OPERATING MANUAL
HAPSITE
®
ER
Chemical Identification System
IPN 074-471-P1B
Vue de la page 0
1 2 3 4 5 6 ... 559 560

Résumé du contenu

Page 1 - OPERATING MANUAL

OPERATING MANUALHAPSITE® ERChemical Identification SystemIPN 074-471-P1B

Page 2

CE Implementation Date: October 2004 Authorized Representative: Duane H. Wright Operations Quality Manager, ISS INFICON Inc.

Page 3

3 - 16 IPN 074-471-P1B HAPSITE ER Operating Manual3.2.1 Changing the Default MethodThe default method for the HAPSITE ER can be changed. By changing

Page 4 - Copyright

3 - 17IPN 074-471-P1BHAPSITE ER Operating Manual3.2.2 Show AllThe HAPSITE will only show methods that are compatible with the current sample and/or

Page 5

3 - 18 IPN 074-471-P1B HAPSITE ER Operating Manual2 When powered on or taken out of Extended Standby, the HAPSITE will automatically start preparing

Page 6

3 - 19IPN 074-471-P1BHAPSITE ER Operating Manual5 Using the touch screen, touch RUN SURVEY. See Figure 3-32.Figure 3-32 Survey Ready6 Alternately,

Page 7

3 - 20 IPN 074-471-P1B HAPSITE ER Operating Manual8 Sample air away from the point of concern for one minute. Remember to note the background TIC. Se

Page 8

3 - 21IPN 074-471-P1BHAPSITE ER Operating Manual10 By touching CMPD ID, a list of identified compounds will appear. See Figure 3-37. The CAS number,

Page 9

3 - 22 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 3-39 Sample GRAPH function13 When the TIC begins to increase, move the probe away from the

Page 10

3 - 23IPN 074-471-P1BHAPSITE ER Operating Manual15 If an Analyze method is not going to be run, touch STOP to stop the sampling process and automati

Page 11 - Warranty

3 - 24 IPN 074-471-P1B HAPSITE ER Operating Manual3.3.1 Quick Reference SOP — Survey Method1 If you are running an Analyze (GC/MS) method after Surv

Page 12

3 - 25IPN 074-471-P1BHAPSITE ER Operating Manual3.4 ANALYZE (GC/MS) Mode with the Concentrator3.4.1 The Tri- Bed ConcentratorThe Tri-Bed concentra

Page 13 - Definition of

WARRANTY AND LIABILITY - LIMITATION: Seller warrants the products manufactured by it, or by an affiliated company and sold by it, and described on the

Page 14

3 - 26 IPN 074-471-P1B HAPSITE ER Operating Manual4 Using the touch screen, touch RUN ANALYZE. See Figure 3-43.Figure 3-43 Analyze Button5 Alternate

Page 15 - Table Of Contents

3 - 27IPN 074-471-P1BHAPSITE ER Operating ManualFigure 3-45 Collecting Sample For Concentrator RunCAUTIONDo not touch the sample with the probe. Do

Page 16 - TOC - 2

3 - 28 IPN 074-471-P1B HAPSITE ER Operating Manual8 By touching CMPD ID, a list of found compounds will appear. See Figure 3-47. This page will displ

Page 17 - Chapter 3

3 - 29IPN 074-471-P1BHAPSITE ER Operating ManualFigure 3-48 Sample Chromatogram View For Concentrator10 A METHOD FINISHED message will appear when

Page 18 - Chapter 4

3 - 30 IPN 074-471-P1B HAPSITE ER Operating Manual3.4.4 Quick Reference SOP —Concentrator Methods1 Verify that the concentrator is installed.2 Refer

Page 19 - TOC - 5

3 - 31IPN 074-471-P1BHAPSITE ER Operating Manual3.5 Detecting Hazardous ChemicalsIf the HAPSITE Analyze message turns red, a chemical’s concentrati

Page 20 - ER IQ Software

3 - 32 IPN 074-471-P1B HAPSITE ER Operating Manual3.5.1 View Results/View ReportsData files and reports can be viewed from the main front panel scre

Page 21 - Data Review

3 - 33IPN 074-471-P1BHAPSITE ER Operating ManualFigure 3-53 Arrow Keys4 To view files from another method, use the SELECT RESULTS button. See Figur

Page 22 - Method Editor

3 - 34 IPN 074-471-P1B HAPSITE ER Operating Manual6 The big blue arrows are used to scroll through the peaks in the chromatogram. The identified comp

Page 23 - Headspace Sampling System

3 - 35IPN 074-471-P1BHAPSITE ER Operating Manual8 Touching a specific compound on the screen will display that compound’s synonym and exposure limit

Page 25 - Service Module

3 - 36 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 3-60 CLOSE 11 Touching the CMPD ID (Compound Identification) button while in Review Results

Page 26 - Maintenance

3 - 37IPN 074-471-P1BHAPSITE ER Operating Manual12 Touching a specific compound in the list will display that compound’s synonym and exposure limits

Page 27 - TOC - 13

3 - 38 IPN 074-471-P1B HAPSITE ER Operating Manual14 To view the Summary, Qualitative and Quantitative Reports, touch the REPORTS button. Alternately

Page 28 - Appendix C

3 - 39IPN 074-471-P1BHAPSITE ER Operating Manual16 The Qualitative Report can be found be touching the QUAL key. See Figure 3-66. Alternately, highl

Page 29 - 1.1 The HAPSITE ER System

3 - 40 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 3-68 Type of Method

Page 30 - 1.3 Serial Number Location

3 - 41IPN 074-471-P1BHAPSITE ER Operating Manual3.6 The Help IconThe Help icon is located on the upper right of the front panel. See Figure 3-69. F

Page 31 - 1.4 Theory of Operation

3 - 42 IPN 074-471-P1B HAPSITE ER Operating Manual3.7 The Info IconThe Info icon is located next to the Help icon in the right hand corner of the up

Page 32 - 1.6.1 Gas Chromatograph

3 - 43IPN 074-471-P1BHAPSITE ER Operating Manual1 An important resource on this database is The NIOSH Pocket Guide to Chemical Hazards (NPG). See Fi

Page 33

3 - 44 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 3-74 NIOSH Pocket Guide

Page 34 - 1.6.2 Mass Spectrometer

3 - 45IPN 074-471-P1BHAPSITE ER Operating Manual3 Scroll down to display an alphabet. Touch the first letter of the desired compound. See Figure 3-7

Page 35

IPN 074-471-P1BHAPSITE ER Operating ManualDefinition ofNote, Hint, Danger, Warning and Caution ParagraphsNOTE: This is a note paragraph. Notes provid

Page 36 - 1.6.3 Vacuum System

3 - 46 IPN 074-471-P1B HAPSITE ER Operating Manual5 Touch the desired chemical. The Pocket Guide for that specific chemical will be displayed. See Fi

Page 37 - 1.6.4 Electronic Systems

3 - 47IPN 074-471-P1BHAPSITE ER Operating Manual7 To access information regarding Immediately Dangerous to Life or Health Concentrations (IDLHs), to

Page 38 - 1.6.5 Software Systems

3 - 48 IPN 074-471-P1B HAPSITE ER Operating Manual9 Scroll down, press DOWN or use the down arrow key to find the desired compound. Press the link to

Page 39 - Box 1 Contents

3 - 49IPN 074-471-P1BHAPSITE ER Operating Manual3.7.1 HAPSITE IconThe HAPSITE icon provides information about the System Parameters and the operati

Page 40 - Box 4 and 5 Contents

3 - 50 IPN 074-471-P1B HAPSITE ER Operating Manual3.7.1.1 Battery IconIf a battery is installed, the Battery icon will display information about the

Page 41

3 - 51IPN 074-471-P1BHAPSITE ER Operating Manual3.7.1.3 Internal Standard IconThe Internal Standard icon uses a vertical bar graph correlate the an

Page 42

3 - 52 IPN 074-471-P1B HAPSITE ER Operating Manual3.7.1.4.1 HEATERS IconTouching the HEATERS icon provides the current temperatures of the column, t

Page 43 - 2.2 Basic Assembly

3 - 53IPN 074-471-P1BHAPSITE ER Operating Manual3.7.1.4.3 CONC ButtonInformation about the concentrator can be found through this button. After tou

Page 44 - 2.2.1 Attaching the Probe

3 - 54 IPN 074-471-P1B HAPSITE ER Operating Manual3.7.1.5 TUNE STATUS IconThis icon provides information about the state of the HAPSITE’s tune. If t

Page 45

3 - 55IPN 074-471-P1BHAPSITE ER Operating Manual3.7.1.5.1 TUNE REPORTSWhen the TUNE STATUS icon has been touched, see Figure 3-93, a button, TUNE R

Page 46 - Figure 2-6 Canister Removal

IPN 074-471-P1B HAPSITE ER Operating ManualOperating Manual Style ConventionsThe following information describes the conventions used throughout this

Page 47 - 2.2.3 Install Battery

3 - 56 IPN 074-471-P1B HAPSITE ER Operating Manual3.7.1.6 GPS IconThe GPS icon will provide the latitude and longitude coordinates of the HAPSITE’s

Page 48 - 2 - 10

3 - 57IPN 074-471-P1BHAPSITE ER Operating Manual3.7.1.7.1 HAPS ButtonThe HAPS button will provide the HAPSITE name, the HAPSITE’s Serial Number, an

Page 49 - 2.3 Helpful Guidelines

3 - 58 IPN 074-471-P1B HAPSITE ER Operating Manual3.7.1.7.3 DATE TIME ButtonThis button displays the present date and time. See Figure 3-99.Figure 3

Page 50 - 2.4 HAPSITE Configurations

3 - 59IPN 074-471-P1BHAPSITE ER Operating ManualThe SKIP HEATER option allows for the HAPSITE to run when the probe is cold. This is useful in cold

Page 51 - 2 - 13

3 - 60 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 3-102 Exit Menu2 The three exit options will be displayed on the screen. There will also be

Page 52 - 2 - 14

3 - 61IPN 074-471-P1BHAPSITE ER Operating ManualFigure 3-104 Confirming Shutdown4 For Turn Off, the screen will become dark and the HAPSITE will tu

Page 53 - Headspace instrument

3 - 62 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 3-105 Extended Standby2 When the screen prompts, Do you want to go into Standby?, touch Yes

Page 54 - 2 - 16

3 - 63IPN 074-471-P1BHAPSITE ER Operating Manual4 When the screen prompts, Do you want to go into Standby?, touch Yes. Alternately, using the arrow

Page 55 - 2.6 Service Module

3 - 64 IPN 074-471-P1B HAPSITE ER Operating Manual3.8.1.1 End Standby1 To End Standby, touch END STANDBY or using the arrow keys, highlight END STAN

Page 56 - 2 - 18

3 - 65IPN 074-471-P1BHAPSITE ER Operating Manual3.9 Analyze (GC/MS) Mode with Headspace Sampling System in Portable ModeThe Headspace Sampling Syst

Page 57 - 2 - 19

TOC - 1IPN 074-471-P1BHAPSITE ER Operating ManualTable Of ContentsTrademarksDefinition of Note, Hint, Danger, Warning and Caution ParagraphsOperatin

Page 58 - 2 - 20

3 - 66 IPN 074-471-P1B HAPSITE ER Operating Manual5 When powered on or taken out of Extended Standby, the HAPSITE will automatically start preparing

Page 59 - 2 - 21

3 - 67IPN 074-471-P1BHAPSITE ER Operating Manual9 Gently push the Headspace needle into the 40 mL vial containing the blank/sample. 10 The screen wi

Page 60 - 2 - 22

3 - 68 IPN 074-471-P1B HAPSITE ER Operating Manual12a The CMPD ID screen can also be accessed by using the arrow keys to highlight CMPD ID and pushin

Page 61 - Right Side View

3 - 69IPN 074-471-P1BHAPSITE ER Operating Manual14 At the end of the Headspace run, a prompt will appear. When prompted Insert needle into a clean v

Page 62 - 2.7 SituProbe

3 - 70 IPN 074-471-P1B HAPSITE ER Operating Manual3.9.1 Quick Reference SOP — GC/MS Mode with HSS in Portable Mode1 Verify that the desired sampling

Page 63

3 - 71IPN 074-471-P1BHAPSITE ER Operating Manual3.10 SituProbeFor complete information on SituProbe methods, see Chapter 14, SituProbe. For instruc

Page 64

3 - 72 IPN 074-471-P1B HAPSITE ER Operating Manual8 Using the touch screen, touch RUN ANALYZE. If using the push buttons, push ANALYZE RUN.Figure 3-1

Page 65

3 - 73IPN 074-471-P1BHAPSITE ER Operating Manual10 The next screen will prompt Sampling is Done. See Figure 3-123. Again, no action is required by t

Page 66

3 - 74 IPN 074-471-P1B HAPSITE ER Operating Manual12 To view the chromatogram while the method is running, touch GRAPH. Alternately, use the arrow ke

Page 67 - Figure 2-40

3 - 75IPN 074-471-P1BHAPSITE ER Operating Manual3.10.2 Quick Reference SOP — GC/MS Mode with SituProbe in Portable Mode1 Verify that the desired sa

Page 68 - 2 - 30

TOC - 2 IPN 074-471-P1B HAPSITE ER Operating Manual2.3 Helpful Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 69 - Figure 2-43 Using Wrench

3 - 76 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 70

4 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 4Wireless and Touch Screen Options4.1 Wireless Option4.1.1 IntroductionThe HAPSITE has a wi

Page 71 - 2.8.1 Probe Nut Assembly

4 - 2 IPN 074-471-P1B HAPSITE ER Operating ManualCAUTIONTo maintain compliance with FCC standards and regulations and to ensure the proper operation

Page 72 - 2.8.2 Attaching a Bag Sample

4 - 3IPN 074-471-P1BHAPSITE ER Operating Manual4.1.3 Regulatory Compliance Information for CANADIAN UsersThis section of the Operating Manual lists

Page 73 - 2 - 35

4 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual4.1.4 Regulatory Compliance Information for EUROPEAN UsersThis section of the Operating Manual list

Page 74

4 - 5IPN 074-471-P1BHAPSITE ER Operating ManualThis symbol indicates that usage restrictions apply to this equipment. Such marking indicates that th

Page 75 - 2.9 Batteries

4 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual4.1.4.3 European Safety Compliance StatementThis device has been tested and certified according to

Page 76 - 2.9.2 Battery Charger

4 - 7IPN 074-471-P1BHAPSITE ER Operating Manual4.1.5 Wireless RangeThe HAPSITE is equipped with an 802.11b/g wireless adapter. The typical range fo

Page 77 - 2 - 39

4 - 8 IPN 074-471-P1B HAPSITE ER Operating ManualDANGERThe HAPSITE contains a wireless transmitter/receiver that emits electromagnetic radiation (EMR

Page 78 - 2 - 40

4 - 9IPN 074-471-P1BHAPSITE ER Operating Manual4.1.7.1 Setting the User Access LevelThe HAPSITE leaves the factory in Normal operating mode. Settin

Page 79 - 2.10 Portable Accessories

TOC - 3IPN 074-471-P1BHAPSITE ER Operating ManualChapter 3Operating HAPSITE in Portable Mode3.1 Starting the HAPSITE in Portable Mode. . . . . . . .

Page 80 - 2.10.2 HAPSITE Backpack

4 - 10 IPN 074-471-P1B HAPSITE ER Operating Manual4.1.8 Wireless Module Indicator LightsLocated on the Wireless Module inside the HAPSITE front cove

Page 81

4 - 11IPN 074-471-P1BHAPSITE ER Operating Manual1 Open the front panel of the HAPSITE.2 Remove the cover from the power switch (for the wireless rad

Page 82

4 - 12 IPN 074-471-P1B HAPSITE ER Operating Manual4.2 The MAIN MenuThe MAIN menu contains the following options: View Results, Smart Interface, Adju

Page 83 - 20%. This will provide an

4 - 13IPN 074-471-P1BHAPSITE ER Operating Manual2 Alternately, use the arrow keys to highlight MAIN and push OK SEL. See Figure 4-7.Figure 4-7 Arro

Page 84 - 2 - 46

4 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual5 To exit the Smart Interface, touch CLOSE. See Figure 4-10.Figure 4-10 Smart Interface4.2.2 Adju

Page 85

4 - 15IPN 074-471-P1BHAPSITE ER Operating Manual2 Touch Adjust Brightness. See Figure 4-12.Figure 4-12 Adjust Brightness3 A scroll bar will appear

Page 86 - Figure 3-3 Details Button

4 - 16 IPN 074-471-P1B HAPSITE ER Operating Manual5 To completely darken the screen, touch Black Screen.Figure 4-15 Black Screen6 To exit the Black

Page 87

4 - 17IPN 074-471-P1BHAPSITE ER Operating Manual4.3 Touch Screen OptionsNOTE: If the Touch Screen freezes, pushing the MENU and ESC keys at the sam

Page 88 - Figure 3-6 Ready Message

4 - 18 IPN 074-471-P1B HAPSITE ER Operating Manual3 Touch Calibrate or push OK SEL when Calibrate is highlighted. See Figure 4-19.Figure 4-19 Calibr

Page 89 - Figure 3-8 Analyze Ready

4 - 19IPN 074-471-P1BHAPSITE ER Operating Manual5 Instructions on screen calibration will appear. Touch OK or highlight OK and push OK SEL. See Figu

Page 90 - Figure 3-10 Arrow Keys

TOC - 4 IPN 074-471-P1B HAPSITE ER Operating Manual3.7.2 Attachments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 91

4 - 20 IPN 074-471-P1B HAPSITE ER Operating Manual7 Touch OK in the next ten seconds if the calibration was accurate for all four targets. Otherwise,

Page 92

4 - 21IPN 074-471-P1BHAPSITE ER Operating Manual2 From the drop-down menu, touch Touch Screen. Alternately, use the arrow keys to highlight Touch Sc

Page 93 - See Figure 3-17

4 - 22 IPN 074-471-P1B HAPSITE ER Operating Manual4.3.2.2 Enabling the Touch Screen1 Using the arrow keys, highlight MAIN and touch OK SEL. See Figu

Page 94 - 3 - 10

4 - 23IPN 074-471-P1BHAPSITE ER Operating Manual4.4 The USB Drive4.4.1 Copying Files to the USBData files can be saved to the USB drive on the HAP

Page 95 - 3 - 11

4 - 24 IPN 074-471-P1B HAPSITE ER Operating Manual4 Touch the USB icon.Touch Copy to USB or using the arrow keys, highlight Copy to USB and push OK S

Page 96

4 - 25IPN 074-471-P1BHAPSITE ER Operating Manual6 Touch the desired file for copying and touch Select. Alternately, use the arrow keys to highlight

Page 97 - 3 - 13

4 - 26 IPN 074-471-P1B HAPSITE ER Operating Manual8 A bar will be displayed on the screen to show the download’s progress. Touch Close to return to t

Page 98 - 3 - 14

4 - 27IPN 074-471-P1BHAPSITE ER Operating Manual4.4.2 Copying Files From the USBThe Copying Files from the USB button can be used to transfer metho

Page 99 - Figure 3-25 Preparing System

4 - 28 IPN 074-471-P1B HAPSITE ER Operating Manual4 Touch the USB icon. Touch COPY FROM USB or using the arrow keys, highlight COPY FROM USB and push

Page 100 - 3 - 16

4 - 29IPN 074-471-P1BHAPSITE ER Operating Manual6 A progress bar will be shown on the screen. Touch Close to return to the USB screen. If another do

Page 101 - 3.3 Survey Mode

TOC - 5IPN 074-471-P1BHAPSITE ER Operating Manual4.4 The USB Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 102 - 3 - 18

4 - 30 IPN 074-471-P1B HAPSITE ER Operating Manual4.4.3 Updating the Front Panel Software from the USBPeriodically, there may be updates to front pa

Page 103 - Figure 3-32 Survey Ready

4 - 31IPN 074-471-P1BHAPSITE ER Operating Manual5 Touch the desired update and touch Select. See Figure 4-43NOTE: If there is not an update file on

Page 104 - 3 - 20

4 - 32 IPN 074-471-P1B HAPSITE ER Operating Manual7 The following screen will be displayed while the system is updating. Touch Done to exit this scre

Page 105 - 3 - 21

4 - 33IPN 074-471-P1BHAPSITE ER Operating Manual4.4.4 Retrieving Files from the USBOnce files have been save to the USB drive, they can be transfer

Page 106 - 3 - 22

4 - 34 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 107 - Figure 3-41 ANALYZE and STOP

5 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 5Operating HAPSITE in Laptop Mode5.1 Starting the HAPSITE in Laptop ModeStarting the HAPSITE

Page 108 - HAPSITE ER Operating Manual

5 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual5.2 Survey ModeThe Survey Mode is used for quick analysis and tentative results. The run period is

Page 109 - 3.4.2 The Tenax Concentrator

5 - 3IPN 074-471-P1BHAPSITE ER Operating Manual3 As part of the HAPSITE’s preparation, it will run AutoTune. If AutoTune successfully runs and compl

Page 110 - 3 - 26

5 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual8 Monitor the Probe distance indicator bar on the HAPSITE screen for guidance. See Figure 5-5. The b

Page 111 - See Figure 3-46

5 - 5IPN 074-471-P1BHAPSITE ER Operating ManualFigure 5-7 Survey Run Complete11 To view the data, note the Data File name and click on the Data Rev

Page 113 - 3 - 29

TOC - 6 IPN 074-471-P1B HAPSITE ER Operating Manual7.5 Manual Tune Settings and Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 114

5 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual5.2.1 Quick Reference SOP — Running Survey Mode1 Double-click the ER IQ software icon.2 Double-clic

Page 115 - Figure 3-50 IDLH Warnings

5 - 7IPN 074-471-P1BHAPSITE ER Operating Manual5.3 Selecting a New Method1 Click the Abort button. See Figure 5-9.Figure 5-9 Aborting Method2 Doub

Page 116 - 3 - 32

5 - 8 IPN 074-471-P1B HAPSITE ER Operating Manual3 Choose a folder that matches the physical configuration of the HAPSITE. In this example, the Conce

Page 117 - Figure 3-55

5 - 9IPN 074-471-P1BHAPSITE ER Operating Manual4 Click the desired method and then, click OK. This example shows the ER_Air_Tri-Bed_PPB_Standard.mth

Page 118 - 3 - 34

5 - 10 IPN 074-471-P1B HAPSITE ER Operating Manual5.4 Analyze (GC/MS) Mode with Concentrator5.4.1 The Tri- Bed ConcentratorThis method is used for

Page 119 - 3 - 35

5 - 11IPN 074-471-P1BHAPSITE ER Operating Manual5 A Concentrator Cleanout will also be run as part of the HAPSITE’s preparation. Hold the probe in a

Page 120 - 3 - 36

5 - 12 IPN 074-471-P1B HAPSITE ER Operating Manual9 When prompted Sampling is Done on the HAPSITE screen, remove the probe from the sample source. Se

Page 121 - Figure 3-63 NIOSH Link

5 - 13IPN 074-471-P1BHAPSITE ER Operating ManualFigure 5-19 Concentrator Run Finished12 Review results at the end of the run. If red lines appear o

Page 122 - 3 - 38

5 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual5.4.3 Quick Reference SOP — Tri-Bed Concentrator Method1 Verify that the Concentrator is installed

Page 123 - 3 - 39

5 - 15IPN 074-471-P1BHAPSITE ER Operating Manual5.5 Analyze (GC/MS) Mode with Headspace Sampling System The Headspace Sampling System is used to te

Page 124 - 3 - 40

TOC - 7IPN 074-471-P1BHAPSITE ER Operating Manual8.9 ER IQ Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 125 - 3.6 The Help Icon

5 - 16 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 5-20 Headspace Needle6 When the HAPSITE has been turned on (refer to section Chapter 3 on p

Page 126 - 3.7 The Info Icon

5 - 17IPN 074-471-P1BHAPSITE ER Operating Manual10 Click RUN button on the pop-up window or from the Control Panel on the screen. Figure 5-22 Run B

Page 127 - 3 - 43

5 - 18 IPN 074-471-P1B HAPSITE ER Operating Manual15 A METHOD FINISHED prompt will appear on the HAPSITE screen when the run is complete. See Figure

Page 128 - 3 - 44

5 - 19IPN 074-471-P1BHAPSITE ER Operating Manual5.5.1 Quick Reference SOP — GC/MS Mode with HSS 1 Double-click the ER IQ software icon.2 Verify tha

Page 129 - See Figure 3-76

5 - 20 IPN 074-471-P1B HAPSITE ER Operating Manual5.6 SituProbe MethodsRefer to the SituProbe Purge and Trap System Operating Manual for more inform

Page 130 - 3 - 46

5 - 21IPN 074-471-P1BHAPSITE ER Operating Manual7 The screen will prompt Collecting Sample Now For. The SituProbe is automatically collecting a samp

Page 131 - Figure 3-79 IDLHs

5 - 22 IPN 074-471-P1B HAPSITE ER Operating Manual10 See Figure 5-31 for an example of a completed chromatogram from the Laptop.Figure 5-31 SituProb

Page 132 - 3 - 48

5 - 23IPN 074-471-P1BHAPSITE ER Operating Manual5.6.2 Quick Reference SOP — Analyze Mode with SituProbe1 Double-click the ER IQ software icon.2 Ver

Page 133 - 3.7.1 HAPSITE Icon

5 - 24 IPN 074-471-P1B HAPSITE ER Operating Manual5.7 Front Panel EmulatorThe HAPSITE ER can be operated using the front panel emulator. This option

Page 134 - 3 - 50

6 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 6Methods6.1 Introduction to MethodsThe versatility of the HAPSITE lies in the variety of met

Page 135 - Figure 3-88 Heaters Icon

TOC - 8 IPN 074-471-P1B HAPSITE ER Operating Manual9.8.5 How to Grab Spectra/Utilize the Full NIST Program . . . . . . . . . . . . . . . . . 9-339.8

Page 136 - 3 - 52

6 - 2 IPN 074-471-P1B HAPSITE ER Operating ManualCAUTIONAll unknown samples should first be collected with the Survey Method to estimate the total VO

Page 137 - Figure 3-91 CONC Button

6 - 3IPN 074-471-P1BHAPSITE ER Operating Manual6.1.3 Building a Survey Method Library FileSurvey methods can be designed for data collection in thr

Page 138 - 3 - 54

6 - 4 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 6-2 Data File Information PageDuring the Calibration run, enter the concentration level of t

Page 139 - 3.7.1.5.1 TUNE REPORTS

6 - 5IPN 074-471-P1BHAPSITE ER Operating ManualThe spectrum of the analyte must be recorded to the Target Compound Library. The spectrum is recorded

Page 140 - 3 - 56

6 - 6 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 6-5 Grab Spectrum for Template WindowThe compound is displayed in the Analytes in Library li

Page 141 - Figure 3-98 FIRMWARE Button

6 - 7IPN 074-471-P1BHAPSITE ER Operating ManualFigure 6-6 Additional Calibration PointsAdditional compounds are added by following the same steps.

Page 142 - 3.7.2 Attachments

6 - 8 IPN 074-471-P1B HAPSITE ER Operating ManualCAUTIONAll unknown samples should first be collected with the Survey Method to avoid saturating the

Page 143 - 3.8 EXIT Menu

7 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 7Tune7.1 Introduction to AutoTune and Manual TuneEnsuring the Mass Spectrometer (MS) perform

Page 144 - 3 - 60

7 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual7.2 AutoTuneThere are two versions of the AutoTune program: Short and Long. The Short AutoTune prog

Page 145 - 3.8.1 Extended Standby

7 - 3IPN 074-471-P1BHAPSITE ER Operating Manual7.2.1 Starting AutoTune from the Manual Tune Screen on the Laptop Computer1 Double-click on the ER I

Page 146 - 3 - 62

TOC - 9IPN 074-471-P1BHAPSITE ER Operating Manual11.7 Full Scan Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 147 - Figure 3-109

7 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual7.3 Viewing a Tune ReportThe Tune Report can be viewed from the front panel display or from the Lap

Page 148 - 3 - 64

7 - 5IPN 074-471-P1BHAPSITE ER Operating ManualTo view the Tune Report from the front panel display, touch the HAPSITE icon and then touch TUNE STAT

Page 149 - Portable Mode

7 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual7.4 AutoTune FailureOccasionally, AutoTune may fail. Follow the procedures outlined below before co

Page 150 - Figure 3-113 HSS Analyze

7 - 7IPN 074-471-P1BHAPSITE ER Operating Manual4 Select default.tun file and press OK. See Figure 7-10.Figure 7-10 Select "default.tun" F

Page 151 - 3 - 67

7 - 8 IPN 074-471-P1B HAPSITE ER Operating Manual6 Highlight default.tun. Click OK. See Figure 7-12.NOTE: This will overwrite the default.tun file. I

Page 152 - 3 - 68

7 - 9IPN 074-471-P1BHAPSITE ER Operating Manual7.5 Manual Tune Settings and ControlsManual Tune is run from the Laptop computer. The Manual Tune sc

Page 153 - Figure 3-118 Purging

7 - 10 IPN 074-471-P1B HAPSITE ER Operating Manual7.5.1 Tool BarFigure 7-14 Manual Tune Tool BarFilament On/Off . . . . . . . . . Turns the Emissi

Page 154 - 3.9.1 Quick Reference SOP —

7 - 11IPN 074-471-P1BHAPSITE ER Operating ManualShow Bounds . . . . . . . . . . . Displays the peak centroid and the target peak width at 10% peak h

Page 155 - 3.10 SituProbe

7 - 12 IPN 074-471-P1B HAPSITE ER Operating ManualShow Tune Status Panel . . . . . . . . Displays the Tune and Mass Calibration Status panel.Show Mas

Page 156 - 3 - 72

7 - 13IPN 074-471-P1BHAPSITE ER Operating ManualShow Target . . . . . . . . . . . . . . . . . . Displays the target bar for the mass peak center an

Page 157 - 3 - 73

TOC - 10 IPN 074-471-P1B HAPSITE ER Operating Manual13.1.3 HSS Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 158 - 3 - 74

7 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual7.5.3 Tune Control PanelFigure 7-17 Tune Control PanelThe Tune Control Panel provides access to d

Page 159 - 3 - 75

7 - 15IPN 074-471-P1BHAPSITE ER Operating Manual7.5.3.1 Tune ParametersEM Volt. . . . . . . . . . . . . . . . . . . . . . . Used to increase or dec

Page 160 - 3 - 76

7 - 16 IPN 074-471-P1B HAPSITE ER Operating ManualShort AutoTune . . . . . . . . . . . . . . . Starts the Short AutoTune functionLong AutoTune . . .

Page 161 - 4.1.1 Introduction

7 - 17IPN 074-471-P1BHAPSITE ER Operating Manual7.5.4.1 Peak Scan Window ControlsMass Adjust . . . . . . . . . . . . Enables the cursor to select

Page 162

7 - 18 IPN 074-471-P1B HAPSITE ER Operating Manual7.5.5 Full Scan WindowThe Full scan window (see Figure 7-19) is used for display purposes to evalu

Page 163

7 - 19IPN 074-471-P1BHAPSITE ER Operating ManualFigure 7-20 Setting the Full Scan RangeDefault Scan ranges of 45 - 300 AMU or 1 - 45 AMU can be sel

Page 164

7 - 20 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 7-22 Tune and Mass Calibration Status MenuMass . . . . . . . . . . . . . . . . . . . . . .

Page 165

7 - 21IPN 074-471-P1BHAPSITE ER Operating ManualMax OK Target Percentage . . . . . . Displays the maximum percentage required for the mass peak to m

Page 166 - ΝΕΙ ΟΤΙ HAPSITE ER Portable

7 - 22 IPN 074-471-P1B HAPSITE ER Operating ManualDiff(mmu) . . . . . . . . . . . . . . . . . . . . Provides an adjustment to DAC value for mass pea

Page 167 - 4.1.6 Turning On the Radio

7 - 23IPN 074-471-P1BHAPSITE ER Operating Manual7.5.8 Right Mouse Button (RMB) MenusIn addition to the functions described above, the following men

Page 168

TOC - 11IPN 074-471-P1BHAPSITE ER Operating Manual14.8.3 Method Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 169

7 - 24 IPN 074-471-P1B HAPSITE ER Operating Manual7.5.8.2 RMB in Tune Status WindowPlacing the Mouse Cursor in the Tune Status panel or the Mass Cal

Page 170 - 4.1.9 Turning Off the Radio

7 - 25IPN 074-471-P1BHAPSITE ER Operating Manual7.6 Performing Manual TuneCAUTIONManual Tune is a procedure that should only be attempted by experi

Page 171 - 4 - 11

7 - 26 IPN 074-471-P1B HAPSITE ER Operating Manual3 Select default.tun file and press OK. See Figure 7-29.Figure 7-29 Select default.tun File4 Wait

Page 172 - 4.2.1 Smart Interface

7 - 27IPN 074-471-P1BHAPSITE ER Operating ManualFigure 7-30 Checking BPG and EM VoltageFigure 7-31 BPG Low

Page 173 - Figure 4-7

7 - 28 IPN 074-471-P1B HAPSITE ER Operating Manual5a If yes, then the BPG does not need adjustment. Proceed to Step 8.5b If no, the BPG will need to

Page 174 - 4.2.2 Adjust Brightness

7 - 29IPN 074-471-P1BHAPSITE ER Operating Manual7.6.2 Adjusting Resolution1 Before adjusting Resolution, Base Peak Gain must be adjusted. Refer to

Page 175 - Figure 4-14 OK Button

7 - 30 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 7-34 Target Percentage Low3b If the red box is in the Max Target Percentage, the Target Res

Page 176 - 4 - 16

7 - 31IPN 074-471-P1BHAPSITE ER Operating Manual2a If the Actual Percentage is above the acceptable range, (red box appears to the right of the colu

Page 177 - 4.3 Touch Screen Options

7 - 32 IPN 074-471-P1B HAPSITE ER Operating Manual3 After making Ion Energy adjustments:3a If the red boxes no longer appear, indicating the Actual R

Page 178 - 4 - 18

7 - 33IPN 074-471-P1BHAPSITE ER Operating ManualFigure 7-38 Tune Saved5 Exit Manual Tune by closing the Tune window. The HAPSITE is ready for sampl

Page 179 - 4 - 19

TOC - 12 IPN 074-471-P1B HAPSITE ER Operating Manual15.7.2 Attaching the HAPSITE to the Service Module using the HAPSITE Front Panel Controls . . .

Page 180 - 4 - 20

7 - 34 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 181 - Figure 4-26 Disable Button

8 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 8ER IQ Software8.1 The HAPSITE Software - ER IQER IQ™ software includes all of the functions

Page 182 - 4 - 22

8 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual8.2 Computer System RequirementsThe following is the minimum recommended laptop computer system for

Page 183 - 4.4 The USB Drive

8 - 3IPN 074-471-P1BHAPSITE ER Operating Manual8.4 Reloading Default HAPSITE MethodsAll of the default methods are saved on the Laptop. These metho

Page 184 - 4 - 24

8 - 4 IPN 074-471-P1B HAPSITE ER Operating ManualER_Air_Tri-Bed_PPM_Standard . . Carbon Concentrator Method to be used in lieu of ER_Air_Loop_PPM_Sta

Page 185 - Figure 4-34 Copy Files

8 - 5IPN 074-471-P1BHAPSITE ER Operating Manual8.4.2 Loading a Default Method to the HAPSITE1 From the Default Methods Menu, select the default met

Page 186 - 4 - 26

8 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual4 Double-click the Analyze folder for Analyze methods (or Survey folder for a Survey method). See Fi

Page 187 - Figure 4-37 Accessories Icon

8 - 7IPN 074-471-P1BHAPSITE ER Operating Manual5 Double-click on the appropriate folder for the method to be saved. See Figure 8-6.NOTE: If using a

Page 188 - 4 - 28

8 - 8 IPN 074-471-P1B HAPSITE ER Operating Manual8.5 Establishing Communications between the HAPSITE and Laptop Computer Establishing communications

Page 189 - Figure 4-40 Progress Bar

8 - 9IPN 074-471-P1BHAPSITE ER Operating ManualFigure 8-9 Add HAPSITE4 The newly added HAPSITE will appear in the HAPSITE List. Press OK. 5 Press O

Page 190 - 4 - 30

TOC - 13IPN 074-471-P1BHAPSITE ER Operating Manual16.11 Battery Charger Maintenance and Troubleshooting. . . . . . . . . . . . . . . . . 16-4416.11.

Page 191 - Figure 4-43 Update From USB

8 - 10 IPN 074-471-P1B HAPSITE ER Operating Manual8.5.2 Configuring the HAPSITE for Communications1 If communication between the HAPSITE and the Lap

Page 192 - 4 - 32

8 - 11IPN 074-471-P1BHAPSITE ER Operating ManualFigure 8-13 Network Connections Standard View5 The Network Connection Status Window will open. Clic

Page 193 - 4 - 33

8 - 12 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 8-14 Local Area Connection Status Window6 In the General tab, scroll down and highlight Int

Page 194 - 4 - 34

8 - 13IPN 074-471-P1BHAPSITE ER Operating Manual7 Select Use the following IP address and enter the IP address of the HAPSITE, (refer to Step 3 on p

Page 195 - Chapter 5

8 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual8.5.3 Establishing Communication with the Service ModuleService Module communications will be esta

Page 196 - 5.2 Survey Mode

8 - 15IPN 074-471-P1BHAPSITE ER Operating ManualWhen Add Port is selected, the window shown in Figure 8-20 will appear. Select the appropriate COM p

Page 197 - Figure 5-4 Run Button

8 - 16 IPN 074-471-P1B HAPSITE ER Operating Manual8.6 Establishing Communications between the HAPSITE and Laptop Computer Using the Wireless Connect

Page 198 - Figure 5-6 Stop Button

8 - 17IPN 074-471-P1BHAPSITE ER Operating Manual4 Select the correct Time Zone from the drop-down list above the map.5 Press OK and reboot the HAPSI

Page 199 - Figure 5-8

8 - 18 IPN 074-471-P1B HAPSITE ER Operating Manual8.8.1 Changing Access LevelsNOTE: When Normal access level is selected, a message will appear stat

Page 200

8 - 19IPN 074-471-P1BHAPSITE ER Operating Manual8.8.2 Setting or Changing the Access Level Password1 To change the Advanced level password, first e

Page 201 - 5.3 Selecting a New Method

TOC - 14 IPN 074-471-P1B HAPSITE ER Operating ManualAppendix CShipping the HAPSITE and ConsumablesC.1 Introduction. . . . . . . . . . . . . . . . . .

Page 202 - See Figure 5-11

8 - 20 IPN 074-471-P1B HAPSITE ER Operating Manual8.9 ER IQ ControlsThe System Setup Page is the main screen of the ER IQ software. The System Setup

Page 203

8 - 21IPN 074-471-P1BHAPSITE ER Operating Manual8.9.1.1 FileThe File drop down menu is shown in Figure 8-32.Figure 8-32 File Menu Selection8.9.1.2

Page 204 - 5.4.2 The Tenax Concentrator

8 - 22 IPN 074-471-P1B HAPSITE ER Operating Manual8.9.1.5 View MenuThe View menu provides selections for displaying and removing parts of the user i

Page 205 - Figure 5-15 Run Button

8 - 23IPN 074-471-P1BHAPSITE ER Operating ManualClick on the ER IQ Information icon to check the software version for the Laptop.Figure 8-35 ER IQ

Page 206 - 5 - 12

8 - 24 IPN 074-471-P1B HAPSITE ER Operating ManualAccesses methods to initiate a run.Accesses the NIST software and library.Accesses the NIOSH Databa

Page 207 - 5 - 13

8 - 25IPN 074-471-P1BHAPSITE ER Operating ManualAccesses Data File information.Returns the current screen to the System Setup screen.Accesses ER IQ

Page 208

8 - 26 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 209 - 5 - 15

9 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 9Data Review9.1 Introduction to Data Review The Data Review section of the ER IQ Laptop soft

Page 210 - Figure 5-20 Headspace Needle

9 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual9.2 Accessing the Data Review FeatureThe Data Review feature can be accessed as follows: Double-cl

Page 211 - 5 - 17

9 - 3IPN 074-471-P1BHAPSITE ER Operating ManualThe Recall window will appear. Select the desired Data File, either from the Laptop or the HAPSITE. S

Page 212 - 5 - 18

1 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 1Introduction1.1 The HAPSITE ER SystemThe HAPSITE® ER Portable Gas Chromatograph and Mass Sp

Page 213 - 5 - 19

9 - 4 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 9-4 Sections of the Data Review ScreenTIC/RIC Window . . . . . . . . . . . . . . . This wind

Page 214 - 5.6 SituProbe Methods

9 - 5IPN 074-471-P1BHAPSITE ER Operating Manual9.3 Data Review ToolbarThe Data Review toolbar is shown in Figure 9-5.Figure 9-5 Data Review Toolba

Page 215 - Figure 5-30 Method Finished

9 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual . . . . . . . . . . . . . . . . . . . . . . . . . Opens AMDIS Program.. . . . . . . . . . . . . . .

Page 216 - 5 - 22

9 - 7IPN 074-471-P1BHAPSITE ER Operating ManualFigure 9-7 RMB Menu in TIC/RIC WindowCommon Scale . . . . . . . . . . . . . . . . When checked, all

Page 217 - 5 - 23

9 - 8 IPN 074-471-P1B HAPSITE ER Operating ManualPeaks gives you the following submenu:Switch to AMDIS. . . . . . . . . . . . Switches to the AMDIS p

Page 218 - 5.7 Front Panel Emulator

9 - 9IPN 074-471-P1BHAPSITE ER Operating Manual9.4.2 RMB in the Spectrum Display WindowWARNINGBe careful not to subtract data/peaks that may be nee

Page 219 - 6.1.2 Survey Method

9 - 10 IPN 074-471-P1B HAPSITE ER Operating ManualUnlock Normalization Cursor . . . . Must be unlocked to move the normalization cursor to a mass oth

Page 220

9 - 11IPN 074-471-P1BHAPSITE ER Operating Manual9.5 The TIC/RIC Display FunctionsThere are tools available to assist in the Data Review process.9.5

Page 221

9 - 12 IPN 074-471-P1B HAPSITE ER Operating Manual9.5.2 How to Use Background Subtraction WARNINGBe careful not to subtract a data/peaks that may be

Page 222

9 - 13IPN 074-471-P1BHAPSITE ER Operating ManualFigure 9-11 Using Background Subtract3 Select the background subtract blue triangle from the lower

Page 223

OPERATING MANUALIPN 074-471-P1BHAPSITE® ERChemical Identification Systemwww.inficon.com [email protected] ©2008 INFICON

Page 224

1 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual1.2 Performance SpecificationsThe performance specifications for the HAPSITE are shown below:Mass r

Page 225 - 6.2 Analyze (GC/MS) Methods

9 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual9.5.2.2 Background Subtraction Using a Range of PointsFigure 9-12 Using Background Subtraction to

Page 226 - Target Compound Library File

9 - 15IPN 074-471-P1BHAPSITE ER Operating Manual9.5.2.3 Additional Features of the Background ToolIf the cursor is placed over B1 or B2, and the Ri

Page 227 - Chapter 7

9 - 16 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 9-14 Using the Range Tool9.5.3.1 Steps Required to Range Acquisition1 Place cursor on the

Page 228 - 7.2 AutoTune

9 - 17IPN 074-471-P1BHAPSITE ER Operating ManualRemove . . . . . . . . . . . . . . . . . . . . . . Removes the Range cursorSelect Mass for Integrati

Page 229 - Computer

9 - 18 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 9-16 Selecting Area to Zoom2 Click and hold the LMB at the point in the TIC where Zoom shou

Page 230 - 7.3 Viewing a Tune Report

9 - 19IPN 074-471-P1BHAPSITE ER Operating Manual9.6.2 Using The Zoom Spectrum FunctionZooming into a Spectrum requires selection of the Zoom button

Page 231 - Figure 7-8 Tune Report

9 - 20 IPN 074-471-P1B HAPSITE ER Operating Manual9.7 Displaying Reconstructed Ion Chromatograms (RIC)RIC plots are useful when locating specific co

Page 232 - 7.4 AutoTune Failure

9 - 21IPN 074-471-P1BHAPSITE ER Operating Manual9.7.1 RIC Plot to Locate Specific CompoundsNOTE: Before running NIST, position the scan cursor over

Page 233

9 - 22 IPN 074-471-P1B HAPSITE ER Operating Manual7 Enter the three largest peaks in the boxes under the Mass (it may also be shown as Ma...) in the

Page 234

9 - 23IPN 074-471-P1BHAPSITE ER Operating ManualFigure 9-27 RIC Plot to Locate Benzene — Three Masses Selected11 The compound was not detected in t

Page 235

1 - 3IPN 074-471-P1BHAPSITE ER Operating Manual1.4 Theory of OperationThe HAPSITE combines two analytical techniques, gas chromatography and mass s

Page 236 - 7.5.1 Tool Bar

9 - 24 IPN 074-471-P1B HAPSITE ER Operating Manual2 The Spectrum will be displayed in the Spectrum window.3 Press the F7 key, or use the RMB to displ

Page 237 - 7.5.2 Tune Drop Down Menu

9 - 25IPN 074-471-P1BHAPSITE ER Operating ManualFigure 9-30 Comparison of NIST and SpectrumIf the Description box is checked, the NIST header infor

Page 238 - 7 - 12

9 - 26 IPN 074-471-P1B HAPSITE ER Operating ManualSelect Peaks. The submenu pops up displaying the choices. See Figure 9-31.Figure 9-31 Peaks Menu C

Page 239 - 7 - 13

9 - 27IPN 074-471-P1BHAPSITE ER Operating ManualFigure 9-33 Post Analysis DisplayIn Figure 9-33, both the Search for Peaks function and the Label t

Page 240 - 7.5.3 Tune Control Panel

9 - 28 IPN 074-471-P1B HAPSITE ER Operating ManualQualitative identification of each peak found by the Search function can be done by checking either

Page 241 - 7 - 15

9 - 29IPN 074-471-P1BHAPSITE ER Operating ManualTo print a report of the results, click on the Report Preview button. This will result in the follow

Page 242 - 7.5.4 Peak Scan Window

9 - 30 IPN 074-471-P1B HAPSITE ER Operating ManualWhen the analyst invokes AMDIS, upon completion of the analysis, the program returns the Results Sc

Page 243 - 7 - 17

9 - 31IPN 074-471-P1BHAPSITE ER Operating ManualFigure 9-38 AMDIS Confirm WindowThis window shows the complete analysis, peak by peak. If there are

Page 244 - 7.5.5 Full Scan Window

9 - 32 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 9-39 NIST Database Search9.8.4 Analyzing Data Using NISTBy right-clicking on the Spectrum

Page 245 - 7 - 19

9 - 33IPN 074-471-P1BHAPSITE ER Operating ManualSwitch to NIST Program (F8). . . . . Starts the full NIST program and will place any files that are

Page 246 - 7 - 20

1 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual1.5 Instrument OverviewThe HAPSITE system is comprised of two modules: the HAPSITE, also known as

Page 247 - 7 - 21

9 - 34 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 9-42 NIST DatabaseNotice the tabs at the bottom of the NIST window. These are multiple wind

Page 248 - 7 - 22

9 - 35IPN 074-471-P1BHAPSITE ER Operating ManualFigure 9-43 View Search Results IconFigure 9-44 Search Reports ScreenThere are a maximum of three

Page 249 - 7 - 23

9 - 36 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 9-45 Qualitative Report in Excel9.9 ER IQ Hot KeysTable 9-1 ER IQ Hot KeysKeys FunctionsC

Page 250 - 7 - 24

9 - 37IPN 074-471-P1BHAPSITE ER Operating ManualCtrl+P PrintPage up Expands the Y Axis view to show twice the current max scale. (If it was 100%, it

Page 251 - 7.6 Performing Manual Tune

9 - 38 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 252 - 7 - 26

10 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 10Saving and Managing Files10.1 Saving Files on the HAPSITEFile types are created two ways,

Page 253 - Figure 7-31 BPG Low

10 - 2 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 10-1 Save Method File Dialog Window - HAPSITE Option SelectedEnter the new file name in the

Page 254

10 - 3IPN 074-471-P1BHAPSITE ER Operating ManualCAUTIONThe HAPSITE ER software is case sensitive. Folder names on the HAPSITE and Laptop must be exa

Page 255 - 7.6.2 Adjusting Resolution

10 - 4 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 10-4 Method Editor - Showing File Name OptionsThe system allows flexibility to add the Date

Page 256

10 - 5IPN 074-471-P1BHAPSITE ER Operating ManualNOTE: Tune files are saved, by default, to the HAPSITE hard drive under the Tune folder.Figure 10-5

Page 257 - 7 - 31

1 - 5IPN 074-471-P1BHAPSITE ER Operating ManualThe inside of the column is coated with a thin layer of a material known as the stationary phase. The

Page 258 - 7 - 32

10 - 6 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 10-7 Save Tune File ScreenOnce the Tune file is saved, the Save Tune File and Manual Tune w

Page 259 - Figure 7-38 Tune Saved

10 - 7IPN 074-471-P1BHAPSITE ER Operating Manual10.1.5 Data ReviewData review is used to view and analyze Data Files. To open files, double-click o

Page 260 - 7 - 34

10 - 8 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 10-10 Data Review Recall WindowThe Data File is opened in the Data Review window, as shown

Page 261

10 - 9IPN 074-471-P1BHAPSITE ER Operating ManualData Files stored on the Laptop may also be opened for review. To open files on the Laptop, select t

Page 262 - Analytical Module Software

10 - 10 IPN 074-471-P1B HAPSITE ER Operating ManualSelecting a different Laptop disk drive is achieved by clicking on the drive drop down box. (Figur

Page 263

10 - 11IPN 074-471-P1BHAPSITE ER Operating ManualOn the Maintain Logs line of Data Settings, enter either indefinitely or the number of days to save

Page 264

10 - 12 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 10-15 Manage Files Icon in System Setup ViewThe Manage Files dialog allows the transfer of

Page 265

10 - 13IPN 074-471-P1BHAPSITE ER Operating ManualFigure 10-17 Manage Files - Rename WindowFiles or folders may be deleted by clicking the file and

Page 266

10 - 14 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 267

11 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 11Method Editor11.1 The Method EditorCAUTIONOnly trained users should create methods. Selec

Page 268 - Laptop Computer

1 - 6 IPN 074-471-P1B HAPSITE ER Operating ManualThe performance of the column is affected by temperature, therefore, the column is housed in a tempe

Page 269 - Figure 8-9 Add HAPSITE

11 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual A Summary page is provided, at the end of the Method Editor, which allows for review and printing

Page 270

11 - 3IPN 074-471-P1BHAPSITE ER Operating ManualThe order of pages that appear in Wizard mode for various collection and analysis modes are listed i

Page 271 - 8 - 11

11 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual11.2 Accessing Method EditorCAUTIONRead all of Chapter 11 before creating a method.To access Metho

Page 272 - 8 - 12

11 - 5IPN 074-471-P1BHAPSITE ER Operating ManualFigure 11-6 Method Editor Description PageMode of AnalysisAnalyze (GC/MS). . . . . . . . . . . . .

Page 273 - 8 - 13

11 - 6 IPN 074-471-P1B HAPSITE ER Operating ManualCollection ModeFull Scan . . . . . . . . . . . . . . . . . . . . . This mode scans all the masses a

Page 274 - 8 - 14

11 - 7IPN 074-471-P1BHAPSITE ER Operating Manual11.3.1 Full Scan MethodA full scan Analyze (GC/MS) method is used for the full identification and q

Page 275 - 8 - 15

11 - 8 IPN 074-471-P1B HAPSITE ER Operating Manual11.3.2 SIM MethodThe SIM Analyze (GC/MS) method is used for the identification and quantitation of

Page 276 - 8 - 16

11 - 9IPN 074-471-P1BHAPSITE ER Operating Manual11.4 Startup PageCAUTIONTemperature settings are critical to get the proper results. Only trained u

Page 277 - 8.8 Access Levels

11 - 10 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 11-8 Method Editor Startup Page for Survey MethodsThe parameters on the Startup page are:U

Page 278 - 8.8.1 Changing Access Levels

11 - 11IPN 074-471-P1BHAPSITE ER Operating ManualProbe . . . . . . . . . . . . . . . . . . . . . . . . The target temperature the Probe must achieve

Page 279 - 8 - 19

1 - 7IPN 074-471-P1BHAPSITE ER Operating Manualmolecules are fractured into smaller molecules, some of which are also ionized. The remaining stream

Page 280 - 8.9.1 System Setup Main Menu

11 - 12 IPN 074-471-P1B HAPSITE ER Operating Manual11.4.1 HeadspaceCAUTIONOnly trained users should create methods. Choosing the incorrect sampling

Page 281 - Figure 8-34 Tools Menu

11 - 13IPN 074-471-P1BHAPSITE ER Operating Manual11.4.2 SituProbeCAUTIONOnly trained users should create methods. Choosing the incorrect sampling d

Page 282 - 8 - 22

11 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual11.5 Inlet PageCAUTIONOnly trained users should modify methods. Changing parameters may result in

Page 283 - 8.11 HAPSITE Icons

11 - 15IPN 074-471-P1BHAPSITE ER Operating ManualFigure 11-12 Method Editor Inlet Page for GC/MS Full ScanOn the Inlet page, the only difference be

Page 284 - 8 - 24

11 - 16 IPN 074-471-P1B HAPSITE ER Operating Manual11.5.1 Inlet StatesCAUTIONOnly trained users should modify methods. Changing inlet states may res

Page 285 - 8 - 25

11 - 17IPN 074-471-P1BHAPSITE ER Operating ManualHINT: When editing from the keyboard, the Alt+Down Arrow key combination will "drop down"

Page 286 - 8 - 26

11 - 18 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 11-15 Valve States for an Inlet State Event

Page 287

11 - 19IPN 074-471-P1BHAPSITE ER Operating ManualFigure 11-16 Customizing the Valve States for an Inlet StateInlet States can be selected from the

Page 288

11 - 20 IPN 074-471-P1B HAPSITE ER Operating ManualThe following choices are available in the Inlet States column:Loopfill . . . . . . . . . . . . .

Page 289

11 - 21IPN 074-471-P1BHAPSITE ER Operating ManualOther . . . . . . . . . . . . . . . . . . . . . . . . This allows the customization of each specifi

Page 290 - Spectrum/Scan

1 - 8 IPN 074-471-P1B HAPSITE ER Operating Manual1.6.3 Vacuum SystemThe mass spectrometer is operated in a vacuum for several reasons.  The ions mu

Page 291 - 9.3 Data Review Toolbar

11 - 22 IPN 074-471-P1B HAPSITE ER Operating ManualHSConcDry . . . . . . . . . . . . . . . . . . . This Inlet State allows dry N2 gas to flow through

Page 292

11 - 23IPN 074-471-P1BHAPSITE ER Operating Manual11.5.2 GC Temperature ProfileCAUTIONOnly trained users should modify methods. Changing GC temperat

Page 293

11 - 24 IPN 074-471-P1B HAPSITE ER Operating Manual11.5.4 Scan EventsCAUTIONOnly trained users should modify methods. Changing parameters may result

Page 294

11 - 25IPN 074-471-P1BHAPSITE ER Operating Manual11.5.5 Concentrator SelectionThere are three selections available for the Concentrator:None . . .

Page 295

11 - 26 IPN 074-471-P1B HAPSITE ER Operating Manual11.6 Tune PageThe Tune Page is divided into two pages, Report and Param, that each provide inform

Page 296 - 9 - 10

11 - 27IPN 074-471-P1BHAPSITE ER Operating ManualFigure 11-22 Method Editor Tune Parameter Page - Show Details

Page 297 - 9 - 11

11 - 28 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 11-23 Method Editor Tune Report Page

Page 298 - 9 - 12

11 - 29IPN 074-471-P1BHAPSITE ER Operating Manual11.7 Full Scan PageCAUTIONOnly trained users should modify methods. Changing parameters may result

Page 299 - 9 - 13

11 - 30 IPN 074-471-P1B HAPSITE ER Operating ManualThe following Mass Spectrometer parameters can be programmed:Start Mass . . . . . . . . . . . . .

Page 300 - 9 - 14

11 - 31IPN 074-471-P1BHAPSITE ER Operating Manual11.8 SIM PageCAUTIONOnly trained users should modify methods. Changing parameters may result in in

Page 301 - 9 - 15

1 - 9IPN 074-471-P1BHAPSITE ER Operating Manual1.6.4 Electronic SystemsThe electronic systems in the HAPSITE are considered in four groups: Mass S

Page 302 - 9 - 16

11 - 32 IPN 074-471-P1B HAPSITE ER Operating ManualSIM for the Analyze (GC/MS) mode allows for creation of multiple sets of masses. Each set has a Be

Page 303 - 9.6 Using the Zoom Function

11 - 33IPN 074-471-P1BHAPSITE ER Operating ManualDwell . . . . . . . . . . . . . . . . . . . . . . . . This is the amount of time the Mass Spectrom

Page 304 - 9 - 18

11 - 34 IPN 074-471-P1B HAPSITE ER Operating Manual11.8.2 SIM for SurveyFigure 11-26 SIM Page, Differences for Survey Analysis

Page 305 - 9 - 19

11 - 35IPN 074-471-P1BHAPSITE ER Operating ManualThe SIM page for Survey mode provides the ability to create only one Scan Set of multiple masses. R

Page 306 - 9 - 20

11 - 36 IPN 074-471-P1B HAPSITE ER Operating Manual11.9 Search PageCAUTIONOnly trained users should modify methods. Depending on the search mode sel

Page 307 - IPN 074-471-P1B

11 - 37IPN 074-471-P1BHAPSITE ER Operating ManualThere are four choices in the Search Mode drop down menu.No Search . . . . . . . . . . . . . . . .

Page 308

11 - 38 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 11-28 AMDIS Search SettingsFigure 11-29 lists the different analysis types available for t

Page 309 - 9.8 NIST Library Searches

11 - 39IPN 074-471-P1BHAPSITE ER Operating Manualof Retention Index standards. In addition to mass spectral data, if the identified compound is not

Page 310 - 9 - 24

11 - 40 IPN 074-471-P1B HAPSITE ER Operating ManualSensitivity . . . . . . . . . . . . . . . . . . . 1-30, used in model peak perception ranges: 30

Page 311 - 9.8.1 Searching Peaks

11 - 41IPN 074-471-P1BHAPSITE ER Operating ManualFigure 11-33 Library OptionsAdvanced SettingsFigure 11-34 Advanced SettingsNOTE: INFICON recommen

Page 312 - 9 - 26

1 - 10 IPN 074-471-P1B HAPSITE ER Operating Manual1.6.5 Software SystemsThe HAPSITE operates with two separate software systems. The instrument itse

Page 313 - Figure 9-34 Results Display

11 - 42 IPN 074-471-P1B HAPSITE ER Operating ManualReject Bin . . . . . . . . . . . . . . . . . . . . Rejects peaks with less than a set number of sc

Page 314 - 9 - 28

11 - 43IPN 074-471-P1BHAPSITE ER Operating ManualWriting a quantitative method still begins with Method Editor, but certain buttons will not be avai

Page 315 - 9.8.3 How To Access AMDIS

11 - 44 IPN 074-471-P1B HAPSITE ER Operating ManualPeak Resolution (dx) . . . . . . . . . . . This number indicates the minimum number of scans betwe

Page 316 - 9 - 30

11 - 45IPN 074-471-P1BHAPSITE ER Operating ManualThe Reset button allows for default values to be reset in the Peak Search window. See Figure 11-38.

Page 317 - 9 - 31

11 - 46 IPN 074-471-P1B HAPSITE ER Operating ManualAMDIS . . . . . . . . . . . . . . . . . . . . . . . When enabled, a concentration can be entered.

Page 318 - 9 - 32

11 - 47IPN 074-471-P1BHAPSITE ER Operating Manual11.10 Data PageThe Data Page provides the capability to customize the data filenames and storage o

Page 319 - 9 - 33

11 - 48 IPN 074-471-P1B HAPSITE ER Operating ManualFile increment digits . . . . . . . . . . . This parameter sets the number of digits used in the

Page 320 - 9 - 34

11 - 49IPN 074-471-P1BHAPSITE ER Operating ManualData File Path . . . . . . . . . . . . . . . . . The entry box for the Data File path is used to sp

Page 321 - 9 - 35

11 - 50 IPN 074-471-P1B HAPSITE ER Operating Manual11.11 Summary PageThe Summary Page, see Figure 11-45, provides selections to show any component,

Page 322 - 9.9 ER IQ Hot Keys

11 - 51IPN 074-471-P1BHAPSITE ER Operating Manual11.12 How to Create a MethodCAUTIONOnly trained users should create Methods. Selecting a parameter

Page 323 - 9 - 37

2 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 2HAPSITE Components and Assemblies2.1 Ship Kit Packing Lists2.1.1 930-850-G9, G12 Ship Kit

Page 324 - 9 - 38

11 - 52 IPN 074-471-P1B HAPSITE ER Operating Manual3 Choose the Method file to be the template for the new Method. Click OK. See Figure 11-48.Figure

Page 325 - 10.1.1 Method Files

11 - 53IPN 074-471-P1BHAPSITE ER Operating ManualFigure 11-49 Save Method File Dialog Window - HAPSITE Option Selected6 On the File Name line, type

Page 326 - 10 - 2

11 - 54 IPN 074-471-P1B HAPSITE ER Operating Manual7a If creating a new folder, name the new folder and then open the new folder before saving the Me

Page 327 - 10.1.3 Data Files

11 - 55IPN 074-471-P1BHAPSITE ER Operating Manual3 Type a new name for the sequenced Method or use the name provided. See Figure 11-54.NOTE: Method

Page 328 - 10.1.4 Tune Files

11 - 56 IPN 074-471-P1B HAPSITE ER Operating Manual5 Choose a Method file to add to the sequence. Click OK. See Figure 11-55.Figure 11-55 Choose Met

Page 329 - 10 - 5

11 - 57IPN 074-471-P1BHAPSITE ER Operating Manual7 In the Start column, choose either Run Button or Immediately for each method. This selection dete

Page 330 - 10 - 6

11 - 58 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 331 - 10.1.5 Data Review

12 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 12Target Compound Methods12.1 Introduction To Quantitative AnalysisQuantitative analysis is

Page 332 - 10 - 8

12 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual12.2 Definition of Terms in the Calibrate WindowFigure 12-1 Calibrate Window12.2.1 MethodBrowse

Page 333 - 10.2.1 Method Files

12 - 3IPN 074-471-P1BHAPSITE ER Operating ManualDisplay. . . . . . . . . . . . . . . . . . . . . . . Displays the chromatogram for the selected Data

Page 334 - 10.2.2 Event Log Files

TrademarksThe trademarks of the products mentioned in this manual are held by the companies that produce them.ConFlat® is a registered trademark of Va

Page 335 - 10.2.5 Report Files

2 - 2 IPN 074-471-P1B HAPSITE ER Operating ManualBox 2 Contents . . . . 930-470-G1 Battery Charger . . . . 24 V Power Supply (see table)Power sup

Page 336 - 10 - 12

12 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual12.2.4 AnalytesAnalytes in Library. . . . . . . . . . . . . Displays the analytes in the libraryAn

Page 337 - 10 - 13

12 - 5IPN 074-471-P1BHAPSITE ER Operating ManualArea . . . . . . . . . . . . . . . . . . . . . . . . . Displays the integrated analyte area quant io

Page 338 - 10 - 14

12 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual12.3 Definition of Terms in the ID Unknowns WindowFigure 12-4 ID Unknowns Window12.3.1 MethodBro

Page 339 - 11.1 The Method Editor

12 - 7IPN 074-471-P1BHAPSITE ER Operating Manual12.3.3 Peak SearchSearch . . . . . . . . . . . . . . . . . . . . . . . Performs a peak detection an

Page 340 - 11 - 2

12 - 8 IPN 074-471-P1B HAPSITE ER Operating ManualCompound . . . . . . . . . . . . . . . . . . . Shows the compound name found in AMDIS, NIST librar

Page 341 - 11 - 3

12 - 9IPN 074-471-P1BHAPSITE ER Operating Manual12.4 Display FunctionThe Display button in the Data Files section of both Calibrate and ID Unknowns

Page 342 - 11.3 Description Page

12 - 10 IPN 074-471-P1B HAPSITE ER Operating Manualbe added, place the cursor in the mass spectrum window and click the Right Mouse Button to open up

Page 343 - 11 - 5

12 - 11IPN 074-471-P1BHAPSITE ER Operating Manual2 After the standard(s) have been prepared, a Method must be developed to collect the data. The met

Page 344 - 11 - 6

12 - 12 IPN 074-471-P1B HAPSITE ER Operating Manual3 After the data has been collected, open the Calibration function which can be accessed by clicki

Page 345 - 11.3.1 Full Scan Method

12 - 13IPN 074-471-P1BHAPSITE ER Operating ManualFigure 12-11 Selecting the Type of Quantitative Method3b Click OK.3c The Method File window will b

Page 346 - 11.3.2 SIM Method

2 - 3IPN 074-471-P1BHAPSITE ER Operating Manual2.1.2 930-850-G10, G11 Ship Kit ContentsThe following items are provided in a typical 930-850-G6, G7

Page 347 - 11.4 Startup Page

12 - 14 IPN 074-471-P1B HAPSITE ER Operating Manualfilled in with the detected peaks. The compounds identified by AMDIS will have Compound names and

Page 348 - 11 - 10

12 - 15IPN 074-471-P1BHAPSITE ER Operating ManualSelect the Right Mouse Button. The options available are:Duplicate Row. . . . . . . . . . . . . . C

Page 349 - 11 - 11

12 - 16 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 12-15 Finished Analytes Chart 10d To finish the template, the concentration of each analyt

Page 350 - 11.4.1 Headspace

12 - 17IPN 074-471-P1BHAPSITE ER Operating ManualFigure 12-17 Save Library Button12 The template is complete and the library is ready for Calibrati

Page 351 - 11.4.2 SituProbe

12 - 18 IPN 074-471-P1B HAPSITE ER Operating Manual12d Additional calibration points can be added to the curve at any time by using the Browse button

Page 352 - 11.5 Inlet Page

12 - 19IPN 074-471-P1BHAPSITE ER Operating Manual1a Selecting ID Unknowns will display the Select File Type dialog box used to select the type of qu

Page 353 - 11 - 15

12 - 20 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 354 - 11.5.1 Inlet States

13 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 13Headspace Sampling System13.1 IntroductionThe Headspace Sampling System (HSS) is an acces

Page 355 - 11 - 17

13 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual13.1.1 How the HSS OperatesThe function of the HSS is to provide consistent partition of analytes

Page 356 - 11 - 18

13 - 3IPN 074-471-P1BHAPSITE ER Operating Manualand moisture from the previous run. During the Purge cycle, the three-way valves change state, assur

Page 357 - 11 - 19

2 - 4 IPN 074-471-P1B HAPSITE ER Operating ManualBox 2 Contents . . . . 930-470-G1 Battery Charger . . . . 24 V Power Supply (see table)Power Sup

Page 358 - 11 - 20

13 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual13.1.4 Consumables RequiredThe following consumables are required for routine analysis when using

Page 359 - 11 - 21

13 - 5IPN 074-471-P1BHAPSITE ER Operating ManualNOTE: Calibration Mixes may be purchased from a variety of laboratory supply businesses in liquid fo

Page 360 - 11 - 22

13 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual13.2 Using the HAPSITE with HSSThe following instructions can be used as a guideline for sample an

Page 361 - 11.5.3 Use Internal Standard

13 - 7IPN 074-471-P1BHAPSITE ER Operating Manual13.2.2 Loading the VialsWARNINGWear appropriate Personal Protection Equipment (PPE) as advised by t

Page 362 - 11.5.4 Scan Events

13 - 8 IPN 074-471-P1B HAPSITE ER Operating Manual5 Adjust the amount of sample in the sample syringe to 20 mL while removing the air bubble. See Fig

Page 363 - 11 - 25

13 - 9IPN 074-471-P1BHAPSITE ER Operating Manual6a Rinse the 10 L syringe, with cemented needle (pictured in Figure 13-6), to be used for the injec

Page 364 - 11.6.2 Report Page

13 - 10 IPN 074-471-P1B HAPSITE ER Operating ManualThe following is a set of examples for amounts of standard mix (at 200 and 2000 g/mL) to be injec

Page 365 - 11 - 27

13 - 11IPN 074-471-P1BHAPSITE ER Operating Manual13.2.3 Loading the WellsThis section describes the procedure for loading a sample into the well of

Page 366 - 11 - 28

13 - 12 IPN 074-471-P1B HAPSITE ER Operating Manual4 Lower the needle, either into an empty well or an empty vial. See Figure 13-8. NOTE: Do not punc

Page 367 - 11.7 Full Scan Page

13 - 13IPN 074-471-P1BHAPSITE ER Operating Manual13.2.5 Making the MeasurementTo make a measurement using the HSS, a method is required. To quantif

Page 368 - 11 - 30

2 - 5IPN 074-471-P1BHAPSITE ER Operating Manual2.1.3 Ship Kits Box 3 and 4Figure 2-1 USA 24V Power Supply (AC To DC Power Converter) - Box 3and Ba

Page 369 - 11.8 SIM Page

13 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual13.3.2.1 Flush ProcedureContamination may be flushed from the HSS by disconnecting the Transfer L

Page 370 - 11 - 32

13 - 15IPN 074-471-P1BHAPSITE ER Operating Manual13.3.3 Cleaning the HSS WellsThe heating block is constructed of aluminum and is normally easy to

Page 371 - 11 - 33

13 - 16 IPN 074-471-P1B HAPSITE ER Operating Manual13.3.4 Decontaminating the HSSThe HSS is designed to be water resistant, but not waterproof. The

Page 372 - 11.8.2 SIM for Survey

13 - 17IPN 074-471-P1BHAPSITE ER Operating Manual13.3.5 Replacing The HSS BatteryReplacement of the battery is performed on an as needed basis. The

Page 373 - 11 - 35

13 - 18 IPN 074-471-P1B HAPSITE ER Operating Manual13.3.6 Replacing The HSS Nitrogen CanisterReplacement of the Nitrogen Canister is on an as needed

Page 374 - 11.9 Search Page

13 - 19IPN 074-471-P1BHAPSITE ER Operating Manual13.5 Charging the HAPSITE Battery using the HSSHAPSITE batteries may be charged one at a time usin

Page 375 - 11 - 37

13 - 20 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 376 - 11 - 38

14 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 14SituProbe14.1 SituProbe The SituProbe™ Purge and Trap System is a sampling accessory for

Page 377 - 11 - 39

14 - 2 IPN 074-471-P1B HAPSITE ER Operating ManualEach compound will partition according to its solubility in the water phase and its vapor pressure.

Page 378 - 11 - 40

14 - 3IPN 074-471-P1BHAPSITE ER Operating Manual14.4 Operating SpecificationsEnvironmental Temperature . . . . . . . Operating: 5 to 45 °C, 0-95% R

Page 379 - Figure 11-33 Library Options

2 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual2.2.1 Attaching the ProbeTo attach the probe line, plug the LEMO® communication line into the port

Page 380 - 11 - 42

14 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual14.5 Consumables 14.5.1 Compressed NitrogenA source of pressurized, ultra high purity Nitrogen is

Page 381 - 11 - 43

14 - 5IPN 074-471-P1BHAPSITE ER Operating Manual14.6 Heated ZonesThere are several heated zones that must be maintained when operating the SituProb

Page 382 - 11 - 44

14 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual14.7 Valves and SequencesThe SituProbe follows a fixed sequence of events to volatilize, transfer,

Page 383 - Figure 11-40 Library Actions

14 - 7IPN 074-471-P1BHAPSITE ER Operating Manuala Concentrator is installed, the HAPSITE’s sampling pathway initially bypasses the Concentrator and

Page 384 - 11 - 46

14 - 8 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 14-3 Method Editor Screen for a Default Open Loop MethodFigure 14-4 Purge Tube14.8.3 Meth

Page 385 - 11.10 Data Page

14 - 9IPN 074-471-P1BHAPSITE ER Operating Manual14.9 Background Cleanup14.9.1 IntroductionThe SituProbe / HAPSITE system, with Concentrator instal

Page 386 - 11 - 48

14 - 10 IPN 074-471-P1B HAPSITE ER Operating ManualHAPSITE . . . . . . . . . . . . . . . . . . . . . A simple troubleshooting step will determine if

Page 387 - 11 - 49

14 - 11IPN 074-471-P1BHAPSITE ER Operating Manual14.10 Operating Tips14.10.1 Reducing BackgroundOperator judgment is the first and best means of r

Page 388 - 11.11 Summary Page

14 - 12 IPN 074-471-P1B HAPSITE ER Operating ManualConcentrator exits the analytical column and crosses the membrane into the Mass Spectrometer, the

Page 389 - 11.12 How to Create a Method

14 - 13IPN 074-471-P1BHAPSITE ER Operating ManualNOTE: The water standard and sample temperatures should be closely matched for similar purging char

Page 390 - 11 - 52

2 - 7IPN 074-471-P1BHAPSITE ER Operating Manual2.2.2 Installing the Gas CanistersCAUTIONOnly open the front panel in a dry, uncontaminated area.The

Page 391 - Figure 11-51

14 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual14.11.3 CalculationsThe following equation can be used to calculate the volume of standard mix th

Page 392

14 - 15IPN 074-471-P1BHAPSITE ER Operating Manual14.13 MaintenancePeriodic cleaning is the only maintenance required for the SituProbe accessory. T

Page 393 - ... button. See Figure 11-54

14 - 16 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 394 - 11 - 56

15 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 15Service Module15.1 IntroductionThe Service Module (also called the SM) provides several s

Page 395 - 11 - 57

15 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual15.2 Service Module Input PowerService Modules are available in either 110/220 V(ac) (IPN 930-202-

Page 396 - 11 - 58

15 - 3IPN 074-471-P1BHAPSITE ER Operating Manual15.3 Components of the Service ModuleThe following section describes the components of both Service

Page 397

15 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual15.3.4 Foreline Vent ValveThe Foreline Vent Valve is located in the middle of the MDP/Turbo Pump.

Page 398 - 12.2.2 Data Files

15 - 5IPN 074-471-P1BHAPSITE ER Operating Manual15.3.8 Power SupplyThe Service Module Power Supply is a 24 V(dc) supply that provides power to the

Page 399 - 12.2.3 Peak Search

15 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual15.4 When to Use the Service ModuleThe Service Module (SM) can be used with the HAPSITE Chemical I

Page 400 - 12.2.5 Reports

15 - 7IPN 074-471-P1BHAPSITE ER Operating Manual15.5 ER IQ Software for the Service ModuleThe ER IQ Laptop software for the Service Module can be a

Page 401 - 12.2.7 Calibration

2 - 8 IPN 074-471-P1B HAPSITE ER Operating Manual2.2.2.1 How to Change or Remove a Gas CanisterPush the lever located on the right of the canister.

Page 402 - 12.3.2 Data Files

15 - 8 IPN 074-471-P1B HAPSITE ER Operating Manual15.5.1 The Service Module Tab in Properties WindowFigure 15-7 Service Module Tab in Properties Wi

Page 403 - 12.3.5 Reports

15 - 9IPN 074-471-P1BHAPSITE ER Operating ManualConfigure . . . . . . . . . . . . . . . . . . . . Allows for times and speeds of Service Module com

Page 404 - 12.3.7 Calibration

15 - 10 IPN 074-471-P1B HAPSITE ER Operating ManualIon Pump Status . . . . . . . . . . . . . . . Displays the Ion Pump usage hours. See Figure 15-10.

Page 405 - 12.4 Display Function

15 - 11IPN 074-471-P1BHAPSITE ER Operating ManualThe following status items are reported in the Service Module Tab Properties Window. Refer to Figur

Page 406 - 12 - 10

15 - 12 IPN 074-471-P1B HAPSITE ER Operating ManualNOTE: If the HAPSITE is already powered on, it does not need to be turned off before placing it on

Page 407 - 12 - 11

15 - 13IPN 074-471-P1BHAPSITE ER Operating Manual15.7.1 Attaching the HAPSITE to the Service Module using the ER IQ SoftwareBe sure to connect the

Page 408 - 12 - 12

15 - 14 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 15-16 Attach Confirmation Request5 The Roughing Pump will start first, then the Turbo Pump

Page 409 - 12 - 13

15 - 15IPN 074-471-P1BHAPSITE ER Operating ManualFigure 15-19 Stop Prepare Button1a If using the push button keys, highlight STOP PREPARE with the

Page 410 - 12 - 14

15 - 16 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 15-21 Service Model Attach Button5 A bar graph displaying the progress of the attach will

Page 411 - 12 - 15

15 - 17IPN 074-471-P1BHAPSITE ER Operating Manual15.8.1 Using ER IQ Software to Detach1 Be sure to connect the HAPSITE to the Laptop using a crosso

Page 412 - 12 - 16

2 - 9IPN 074-471-P1BHAPSITE ER Operating Manual2.2.3 Install BatteryInsert the battery by sliding it into the rectangular opening to the left of th

Page 413 - 12 - 17

15 - 18 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 15-26 Detach In Process5 The HAPSITE Vacuum Interconnect valve will close shortly after se

Page 414 - 1 Click the ID Unknowns icon

15 - 19IPN 074-471-P1BHAPSITE ER Operating Manual15.9 Physically Removing the HAPSITE from the Service ModuleThe HAPSITE cannot be physically remov

Page 415 - 12 - 19

15 - 20 IPN 074-471-P1B HAPSITE ER Operating Manual15.10 Storing the Service ModuleWhen not attached to the HAPSITE, the Service Module should be st

Page 416 - 12 - 20

15 - 21IPN 074-471-P1BHAPSITE ER Operating ManualTo place the Service Module in storage, the aluminum storage plug is placed on the opening where th

Page 417 - 13.1 Introduction

15 - 22 IPN 074-471-P1B HAPSITE ER Operating ManualThe prompt shown will appear to confirm pumping down the Service Module. See Figure 15-32.Figure 1

Page 418 - 13.1.1 How the HSS Operates

15 - 23IPN 074-471-P1BHAPSITE ER Operating ManualTo complete the Service Module storage procedure, turn off the Service Module power switch at the b

Page 419 - 13.1.3 HSS Indicators

15 - 24 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 420 - 13.1.4 Consumables Required

16 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 16Maintenance16.1 IntroductionThe HAPSITE instrument is designed to require minimal service

Page 421 - 13 - 5

16 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual16.2 Safety ConsiderationsWARNINGWhen operating, the NEG pump is hot! Do not bypass the programmed

Page 422 - 13.2.1 Powering on the HSS

16 - 3IPN 074-471-P1BHAPSITE ER Operating Manual16.3 HAPSITE Symptom - Cause - Remedy ChartTable 16-1 Diagnosing Problems - HAPSITESymptom Cause R

Page 423 - 13.2.2 Loading the Vials

2 - 10 IPN 074-471-P1B HAPSITE ER Operating Manual2.2.5 Connect Laptop (if desired)The HAPSITE ER has two possible configurations for connecting to

Page 424 - 13 - 8

16 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual4c. Make sure that there is a full unexpired internal standard canister in the GC, and make sure th

Page 425 - 13 - 9

16 - 5IPN 074-471-P1BHAPSITE ER Operating Manual9d. Check turbo speed in Service Module program, If less then 1480 Hz, Service Module pumps may need

Page 426

16 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual17. Temperature zone fail to heat. 17a. Open heater, or bad controller card. 17a. Contact Customer

Page 427 - 13.2.3 Loading the Wells

16 - 7IPN 074-471-P1BHAPSITE ER Operating Manual16.4 Required Environment for General MaintenanceThe HAPSITE is designed for use in the field, away

Page 428 - 13.2.4 Cycling the Vials

16 - 8 IPN 074-471-P1B HAPSITE ER Operating Manual16.5.1 Contamination of the Mass SpectrometerContamination of the Mass Spectrometer manifold can o

Page 429 - 13.3 Maintenance of the HSS

16 - 9IPN 074-471-P1BHAPSITE ER Operating Manual16.5.3 Contamination of the Probe and Probe LineContamination of the Probe and Probe Line can occur

Page 430 - 13 - 14

16 - 10 IPN 074-471-P1B HAPSITE ER Operating Manual4 With each end of the probe in a separate hand, move the probe handle up and down until methanol

Page 431 - 13 - 15

16 - 11IPN 074-471-P1BHAPSITE ER Operating Manual16.5.4 Decontaminating the Outside of the Analytical Module1 Decontamination cap and plug kit numb

Page 432

16 - 12 IPN 074-471-P1B HAPSITE ER Operating Manual4 Install the green load lock cover (P/N 930-308-P1). See Figure 16-5.Figure 16-5 Green Load Lock

Page 433 - 13 - 17

16 - 13IPN 074-471-P1BHAPSITE ER Operating ManualCAUTIONAll caps must be in place and the front door must be firmly shut before decontaminating the

Page 434 - 13.4 Shipping the HSS

2 - 11IPN 074-471-P1BHAPSITE ER Operating Manual2.3 Helpful GuidelinesA set of helpful guidelines to keep the HAPSITE safe and operational.DON’T…

Page 435 - 13 - 19

16 - 14 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 16-8 Pressure Location on HAPSITEFigure 16-9 MS Pressure on the LaptopA MS Vacuum Pressur

Page 436 - 13 - 20

16 - 15IPN 074-471-P1BHAPSITE ER Operating Manual16.6.1 Bakeout ProcedureA bakeout can be performed with or without the use of the Service Module.

Page 437 - 14.2 Theory

16 - 16 IPN 074-471-P1B HAPSITE ER Operating Manual16.6.2 Reactivating the NEG PumpReactivating the NEG Pump requires having the Service Module atta

Page 438 - 14.3 Physical Specifications

16 - 17IPN 074-471-P1BHAPSITE ER Operating ManualFigure 16-13 Service Window4 Click the Activate NEG button. 5 At the end of the reactivation, the

Page 439 - 14 - 3

16 - 18 IPN 074-471-P1B HAPSITE ER Operating Manual16.7.1 Required Tools and Equipment Service Module Laptop computer New NEG Pump. 1/4” Allen w

Page 440 - 14.5.1 Compressed Nitrogen

16 - 19IPN 074-471-P1BHAPSITE ER Operating Manual16.7.2 Part 1: NEG Pump Removal1 This procedure requires the use of a Service Module. The HAPSITE

Page 441 - 14.6 Heated Zones

16 - 20 IPN 074-471-P1B HAPSITE ER Operating ManualWARNINGThe NEG Pump becomes very hot when in operation. The software-controlled sequence to remove

Page 442 - 14.7.2 Purge

16 - 21IPN 074-471-P1BHAPSITE ER Operating Manual6 Remove chain clamp.7 Pull the NEG Pump out.NOTE: The aluminum gasket can not be reused. Bend the

Page 443 - 14.8.2 Purge Rate Adjustment

16 - 22 IPN 074-471-P1B HAPSITE ER Operating Manual3 Wearing safety glasses and gloves, clean the o-ring on the VI valve with methanol. See Figure 16

Page 444 - 14.8.3 Method Events

16 - 23IPN 074-471-P1BHAPSITE ER Operating Manual5 Replace the VI valve into the bottom of manifold. Hand tighten. See Figure 16-20.Figure 16-20 Re

Page 445 - 14.9.2 Cleanup Steps

DECLARATION OF CONFORMITY This is to certify that this equipment, designed and manufactured by: INFICON Inc. Two Technology Place

Page 446 - 14 - 10

2 - 12 IPN 074-471-P1B HAPSITE ER Operating Manual2.4 HAPSITE ConfigurationsThere are six basic configurations for the HAPSITE. The first three can

Page 447 - 14.10.2 Nitrogen Usage

16 - 24 IPN 074-471-P1B HAPSITE ER Operating Manual16.7.4 Part 3: Install the New NEG PumpWARNINGGloves must be worn while performing all of the fol

Page 448 - 14.11.2 Standard Preparation

16 - 25IPN 074-471-P1BHAPSITE ER Operating Manual2 Remove the new NEG Pump and aluminum gasket from the shipping container. See Figure 16-23.Figure

Page 449 - 14 - 13

16 - 26 IPN 074-471-P1B HAPSITE ER Operating Manual4 Remove the new NEG Pump from the protective container. See Figure 16-25.CAUTIONThe NEG Pump is s

Page 450 - 14.12 Calibration Curves

16 - 27IPN 074-471-P1BHAPSITE ER Operating Manual7 Save the rubber “O” ring assembly and container to dispose of the old NEG Pump.8 Place the new al

Page 451 - 14.13.1 Surface Cleaning

16 - 28 IPN 074-471-P1B HAPSITE ER Operating Manual10 Replace the chain clamp insuring that the nut points to the left. Use the torque wrench and tig

Page 452 - 14 - 16

16 - 29IPN 074-471-P1BHAPSITE ER Operating Manual11 Place the old NEG Pump into the protective container with the o-ring assembly and place back in

Page 453 - 15.1 Introduction

16 - 30 IPN 074-471-P1B HAPSITE ER Operating Manual16.7.5 Part 4: Leak Check of the Vacuum SystemCAUTIONChecking for leaks is very important. Air le

Page 454 - 15 - 2

16 - 31IPN 074-471-P1BHAPSITE ER Operating ManualFigure 16-33 Select "default.tun" File4 Wait for the automated process of opening tune t

Page 455 - 15.3.3 Manifold Vent Valve

16 - 32 IPN 074-471-P1B HAPSITE ER Operating Manual7 Close the Tune Status Panel and the Mass Calibration Status by deselecting each. See Figure 16-3

Page 456 - 15.3.7 Battery Charger

16 - 33IPN 074-471-P1BHAPSITE ER Operating Manual10 Select Custom. Type in a range of 60 to 90. This will enable the analyst to scan for both the 69

Page 457 - 15.3.9 Communications

2 - 13IPN 074-471-P1BHAPSITE ER Operating ManualTransfer Line Insulation (INFICON part number 931-405-P1) — This foam sleeve is used as insulation f

Page 458 - 15 - 6

16 - 34 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 16-40 Short Tune Icon15 Follow with section 16.7.6, Part 5: Activation of the NEG Pump, on

Page 459 - Figure 15-5 Status Icon

16 - 35IPN 074-471-P1BHAPSITE ER Operating ManualFigure 16-42 Service Window4 Select Activate NEG. 5 When prompted on the Front Panel, enter the Se

Page 460 - 15 - 8

16 - 36 IPN 074-471-P1B HAPSITE ER Operating Manualprocess. If a NEG has greater than 50 hours (approximately 1/2 the expected life) the more economi

Page 461 - Figure 15-8 Configure Window

16 - 37IPN 074-471-P1BHAPSITE ER Operating ManualFigure 16-43 Vent HAPSITE from ER IQ SoftwareCAUTIONThe NEG Pump becomes very hot when in operatio

Page 462 - 15 - 10

16 - 38 IPN 074-471-P1B HAPSITE ER Operating Manual5 To loosen the chain clamp, turn the nut counter-clockwise until loose. See Figure 16-16.Figure 1

Page 463 - 15 - 11

16 - 39IPN 074-471-P1BHAPSITE ER Operating ManualCAUTIONMake sure all tools are clean by wiping them with methanol. Wear powder free gloves for the

Page 464 - 15 - 12

16 - 40 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 16-47 Extension Tube Slid into the Ion Volume13 Use the flat head screw driver to loosen t

Page 465

16 - 41IPN 074-471-P1BHAPSITE ER Operating Manual18 Tighten the three securing screws with the screw driver. Tighten them alternately and gently to

Page 466 - Front Panel Controls

16 - 42 IPN 074-471-P1B HAPSITE ER Operating Manual3 Remove the top cover of the needle assembly to expose the needle and the 1/4" connection fi

Page 467 - 15 - 15

16 - 43IPN 074-471-P1BHAPSITE ER Operating ManualFigure 16-51 Holding Down the Needle while Tightening the Nuts (So Ferrules Seat Properly)9 Now th

Page 468 - 15.8 Detaching the HAPSITE

2 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual4 Plug one end of the Y-cable into the HAPSITE 24 V(dc) connector.5 Plug the other end of the Y-cab

Page 469 - 15 - 17

16 - 44 IPN 074-471-P1B HAPSITE ER Operating Manual16.11 Battery Charger Maintenance and TroubleshootingWARNING - Risk Of Electric ShockDo not attem

Page 470

16 - 45IPN 074-471-P1BHAPSITE ER Operating Manual16.11.2.2 If the Red Indicator is FlashingThis indicates that the Battery Charger is unable to com

Page 471 - 15 - 19

16 - 46 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 472 - 15 - 20

17 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 17Customer Support17.1 How To Contact Customer SupportWorldwide support information regardi

Page 473 - 15 - 21

17 - 2 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 474 - 15 - 22

18 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 18Part Numbers18.1 HAPSITE Part NumberTable 18-1 Part Number Product Feature Options HSER9

Page 475 - 15.12 Routine Maintenance

18 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual18.2 HAPSITE ER Accessories Service Module930-202-G1 . . . . . . . . . . . . . . . . 100/120/230

Page 476 - 15 - 24

18 - 3IPN 074-471-P1BHAPSITE ER Operating ManualLine Insulation070-1545 . . . . . . . . . . . . . . . . . . Probe InsulationNIST930-4071-G1 . . .

Page 477 - 16.1 Introduction

18 - 4 IPN 074-471-P1B HAPSITE ER Operating ManualCombo Pack Canisters 930-477-P1. . . . . . . . . . . . . . . . . Gas Combo Pack (4 Carrier Gas and

Page 478 - 16.2 Safety Considerations

18 - 5IPN 074-471-P1BHAPSITE ER Operating Manual18.5 Service Module Spare Parts 068-0002 . . . . . . . . . . . . . . . . . . . . . Battery Charger

Page 479 - Symptom Cause Remedy

2 - 15IPN 074-471-P1BHAPSITE ER Operating ManualFigure 2-13 Attaching the Transfer Line to the Back of the HSSFigure 2-14 Attaching Transfer Line

Page 480 - 16 - 4

18 - 6 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 481

19 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 19Glossary19.1 GlossaryAir peak . . . . . . . . . . . . . . . . . . . . . . A response by t

Page 482 - 20a. Leak in system

19 - 2 IPN 074-471-P1B HAPSITE ER Operating ManualCarrier Gas . . . . . . . . . . . . . . . . . . . The pure inorganic gas used to aid the flow of sa

Page 483 - 16.5 Contamination

19 - 3IPN 074-471-P1BHAPSITE ER Operating ManualElution time. . . . . . . . . . . . . . . . . . . The time from injection of a specific compound ont

Page 484 - 16 - 8

19 - 4 IPN 074-471-P1B HAPSITE ER Operating ManualFull Method . . . . . . . . . . . . . . . . . . . Full method allows the user to specify a range of

Page 485 - 16 - 9

19 - 5IPN 074-471-P1BHAPSITE ER Operating ManualInlet State . . . . . . . . . . . . . . . . . . . . This refers to a specification of the state of

Page 486

19 - 6 IPN 074-471-P1B HAPSITE ER Operating ManualLibrary . . . . . . . . . . . . . . . . . . . . . . . A user compiled list of compounds, which incl

Page 487 - Figure 16-3 Plugs and Caps

19 - 7IPN 074-471-P1BHAPSITE ER Operating ManualNIST Library . . . . . . . . . . . . . . . . . . NIST stands for National Institute of Standards an

Page 488

19 - 8 IPN 074-471-P1B HAPSITE ER Operating ManualRecalculate . . . . . . . . . . . . . . . . . . . An option in the Calibration section of the Run M

Page 489 - 16.6 NEG Troubleshooting

19 - 9IPN 074-471-P1BHAPSITE ER Operating Manual% RSD . . . . . . . . . . . . . . . . . . . . . . . Percent Relative Standard Deviation. This is a m

Page 490 - 16 - 14

2 - 16 IPN 074-471-P1B HAPSITE ER Operating Manual9 If using the HSS in portable mode, a battery will need to be installed. Open the front door of th

Page 491 - 16.6.1 Bakeout Procedure

19 - 10 IPN 074-471-P1B HAPSITE ER Operating ManualSituProbe . . . . . . . . . . . . . . . . . . . . The SituProbe Purge and Trap System is a sampli

Page 492 - 16 - 16

19 - 11IPN 074-471-P1BHAPSITE ER Operating ManualTune . . . . . . . . . . . . . . . . . . . . . . . . . A term (noun or verb) which generally refers

Page 493 - Figure 16-13 Service Window

19 - 12 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 494 - 16 - 18

A - 1IPN 074-471-P1BHAPSITE ER Operating ManualAppendix AHAPSITE Target CompoundsA.1 Compounds In Order Of Elution Name Formula k Quantion I.S. C

Page 495 - 16 - 19

A - 2 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 496 - 16 - 20

B - 1IPN 074-471-P1BHAPSITE ER Operating ManualAppendix BCalibrating Gas MixturesB.1 Acquisition, Preparation, and HandlingCAUTIONFailure to calibr

Page 497 - 16 - 21

B - 2 IPN 074-471-P1B HAPSITE ER Operating ManualB.1.1.1 Using Cylinders Charged with Each ConcentrationTo perform a calibration, have the known gas

Page 498 - 16 - 22

B - 3IPN 074-471-P1BHAPSITE ER Operating ManualB.1.1.2 Diluting the Gas On SiteThe comments above, concerning hardware, relate as well to the case

Page 499 - 16 - 23

B - 4 IPN 074-471-P1B HAPSITE ER Operating ManualB.1.2.1 Free Flow of GasThe free flow of gas from the regulator of a pressure cylinder is reduced t

Page 500 - 16 - 24

B - 5IPN 074-471-P1BHAPSITE ER Operating Manualon-off valves on the Tedlar bags (such as on 231 -XX series bags by SKC5, Inc.) should minimize any f

Page 501 - 16 - 25

2 - 17IPN 074-471-P1BHAPSITE ER Operating Manual2.6 Service ModuleThe Service Module is used to create a vacuum in the HAPSITE. It cannot be used i

Page 502 - 16 - 26

B - 6 IPN 074-471-P1B HAPSITE ER Operating ManualTedlar bags may be cleaned for reuse, or replaced with new bags. To clean a Tedlar bag for use with

Page 503 - 16 - 27

C - 1IPN 074-471-P1BHAPSITE ER Operating ManualAppendix CShipping the HAPSITE and ConsumablesC.1 IntroductionThe HAPSITE instrument and its Service

Page 504 - 16 - 28

C - 2 IPN 074-471-P1B HAPSITE ER Operating Manualeasiest approach is to contact INFICON and order the required gases to be shipped directly to the si

Page 505 - Figure 16-30 Old NEG Pump

C - 3IPN 074-471-P1BHAPSITE ER Operating ManualAlthough the airline will carry the box of canisters in the same cargo hold as the baggage, they will

Page 507 - 16 - 31

Index - 1IPN 074-471-P1BHAPSITE ER Operating ManualIndexSymbols% RSD 19-9AAC to DC power converter 2-9airleak 16-3, 16-5samples 1-6alignment 19-1AMD

Page 508 - 16 - 32

Index - 2 IPN 074-471-P1B HAPSITE ER Operating Manualcurve statistics 12-4Customer SupportCustomer Service 17-1Repair Service 17-1Return Material Aut

Page 509 - 16 - 33

Index - 3IPN 074-471-P1BHAPSITE ER Operating ManualHot Swap Cable 2-43HSPurge 11-21HSS 1-1, 2-12, 5-15, 19-4AC to CD Power 2-13battery 2-16battery c

Page 510 - 16 - 34

Index - 4 IPN 074-471-P1B HAPSITE ER Operating Manualmethanol 14-12, 16-22method 19-6development 11-3, 12-11sequencing 11-54wizard 11-2Method EditorI

Page 511 - Figure 16-42 Service Window

Index - 5IPN 074-471-P1BHAPSITE ER Operating Manualresolution 11-40, 19-8response factor 12-1, 12-4retention time 1-5, 12-1, 19-8reverse search 19-8

Page 512

2 - 18 IPN 074-471-P1B HAPSITE ER Operating ManualThe Service Module requires a power cable and a RS-232 communications cable to allow communication

Page 513 - 16 - 37

Index - 6 IPN 074-471-P1B HAPSITE ER Operating ManualTTargetlibrary 6-4Tedlar bag B-4, B-6temperatureramp 11-23Tenax concentrator 11-25threshold 19-1

Page 514

2 - 19IPN 074-471-P1BHAPSITE ER Operating Manual1 Attach the RS-232 communications cable to the Service Module, as shown in Figure 2-20. Figure 2-20

Page 515

2 - 20 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 2-22 System Setup Screen with Service ModuleNOTE: If the Service Module icon does not appea

Page 516

2 - 21IPN 074-471-P1BHAPSITE ER Operating ManualFigure 2-24 Cleaning the Service Module Rubber O-ring using a Lint-free WipeAfter cleaning the rubb

Page 517 - 16 - 41

Immunity: EN 61326:2006 (EMC – Measurement, Control & Laboratory Equipment) Class A: Immunity per Table A.1 ETSI EN 3

Page 518

2 - 22 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 2-25 Remove the Green Plastic Protective Cover on the Bottom of the HAPSITEFigure 2-26 show

Page 519 - 16 - 43

2 - 23IPN 074-471-P1BHAPSITE ER Operating ManualFigure 2-27 Service Module - Showing Latch on Right SideFigure 2-28 shows the HAPSITE attached to t

Page 520 - 16 - 44

2 - 24 IPN 074-471-P1B HAPSITE ER Operating Manual2.6.3 Detaching the HAPSITE from the Service ModuleCarefully follow the procedures starting with s

Page 521 - 16 - 45

2 - 25IPN 074-471-P1BHAPSITE ER Operating Manual4 Connect the end of the SituProbe Transfer Line to the HAPSITE at the same location where the probe

Page 522 - 16 - 46

2 - 26 IPN 074-471-P1B HAPSITE ER Operating Manual6 OPTIONAL: Insert a charged battery into the SituProbe accessory battery slot. The battery is not

Page 523 - Customer Support

2 - 27IPN 074-471-P1BHAPSITE ER Operating Manual12 The SituProbe accessory (IPN 932-220-G1) displays water level conditions in the purge head. Green

Page 524 - 17 - 2

2 - 28 IPN 074-471-P1B HAPSITE ER Operating ManualNOTE: The Tenax Concentrator does not have a specific orientation. See Figure 2-38.Figure 2-38 Ten

Page 525 - 18.1 HAPSITE Part Number

2 - 29IPN 074-471-P1BHAPSITE ER Operating ManualFigure 2-39 Placing Concentrator in Bottom Elbow4 For the Tribed Concentrator: Carefully lift up on

Page 526 - 18.2 HAPSITE ER Accessories

2 - 30 IPN 074-471-P1B HAPSITE ER Operating Manual5 Keep the Concentrator aligned between the two elbow fittings while gently pressing down on the to

Page 527 - 18.3 HAPSITE Consumables

2 - 31IPN 074-471-P1BHAPSITE ER Operating ManualFigure 2-43 Using Wrench8 Place the black Concentrator Cover (see Figure 2-44) over the Concentrato

Page 528 - 18.4 Headspace Spare Parts

DECLARATION OF CONFORMITY This is to certify that this equipment, designed and manufactured by: INFICON Inc. Two Technology Place

Page 529 - 18 - 5

2 - 32 IPN 074-471-P1B HAPSITE ER Operating ManualNOTE: The Concentrator Cover contains two metal contacts, inspect the contacts, prior to assembly,

Page 530 - 18 - 6

2 - 33IPN 074-471-P1BHAPSITE ER Operating Manual2.8 Probe Sampling Options and AttachmentsTo expand the sampling range of the HAPSITE, sample colle

Page 531 - 19.1 Glossary

2 - 34 IPN 074-471-P1B HAPSITE ER Operating Manual2.8.2 Attaching a Bag SampleWhen samples are collected to be run later, various sampling bags can

Page 532 - 19 - 2

2 - 35IPN 074-471-P1BHAPSITE ER Operating Manual2.8.3 VX / R-33 Conversion TubeThis procedure describes the steps required to prepare the HAPSITE t

Page 533 - 19 - 3

2 - 36 IPN 074-471-P1B HAPSITE ER Operating Manual3 Insert either end of the VX-G Conversion Tube into the nut. Make sure the tube is firmly seated i

Page 534 - 19 - 4

2 - 37IPN 074-471-P1BHAPSITE ER Operating Manual2.9 BatteriesThe battery provides power to the HAPSITE to allow portability. Under optimum conditio

Page 535 - 19 - 5

2 - 38 IPN 074-471-P1B HAPSITE ER Operating Manual2.9.2 Battery ChargerThe auxiliary Battery Charger (part number 930-470-G1—see Figure 2-52) charge

Page 536 - 19 - 6

2 - 39IPN 074-471-P1BHAPSITE ER Operating Manual2.9.2.1 Battery Charger ComponentsThe Battery Charger is shipped with a power cord and spare fuses.

Page 537 - 19 - 7

2 - 40 IPN 074-471-P1B HAPSITE ER Operating ManualAmber . . . . . . . . . . . . . . . . . . . . . . . The battery is fully charged. The rate of charg

Page 538 - 19 - 8

2 - 41IPN 074-471-P1BHAPSITE ER Operating Manual2.10 Portable AccessoriesPortability is an important HAPSITE feature. The following accessories fac

Page 539 - 19 - 9

CE Implementation Date: March 31, 2006 Authorized Representative: Duane H. Wright Operations Quality Manager, ISS INFICON Inc.

Page 540 - 19 - 10

2 - 42 IPN 074-471-P1B HAPSITE ER Operating Manual2.10.2 HAPSITE BackpackThe backpack is a light weight, high quality hiker’s backpack. It has been

Page 541 - 19 - 11

2 - 43IPN 074-471-P1BHAPSITE ER Operating Manual2.10.2.2 Care of the Backpack Avoid exposing the backpack to solvents and other active chemicals.

Page 542 - 19 - 12

2 - 44 IPN 074-471-P1B HAPSITE ER Operating ManualWARNING - Risk Of Electric ShockDo not use if the "L" connector is broken. WARNING - Risk

Page 543 - HAPSITE Target Compounds

2 - 45IPN 074-471-P1BHAPSITE ER Operating Manual2.11.2 Storing the Hot Swap CableThe Hot Swap Cable and Battery have exposed electrical connections

Page 544

2 - 46 IPN 074-471-P1B HAPSITE ER Operating ManualThis page is intentionally blank.

Page 545 - Calibrating Gas Mixtures

3 - 1IPN 074-471-P1BHAPSITE ER Operating ManualChapter 3Operating HAPSITE in Portable Mode3.1 Starting the HAPSITE in Portable ModePortable Mode re

Page 546

3 - 2 IPN 074-471-P1B HAPSITE ER Operating Manual4 The HAPSITE will begin to prepare various components. These components include heating the HAPSITE

Page 547 - 4.Alltech: (800) 255-8324

3 - 3IPN 074-471-P1BHAPSITE ER Operating Manual7 The progress of the preparation is shown by a bar graph. If a component is in the process of being

Page 548

3 - 4 IPN 074-471-P1B HAPSITE ER Operating Manual11 When the HAPSITE is ready to run samples, a green SYSTEM READY, SURVEY READY or ANALYZE READY mes

Page 549 - 5.SKC: (800) 752-8472

3 - 5IPN 074-471-P1BHAPSITE ER Operating Manual12 If SURVEY READY is displayed, touch RUN SURVEY or push SURVEY RUN. Figure 3-7 Survey Ready13 If A

Page 550 - L. This corresponds to

DECLARATION OF CONFORMITY This is to certify that this equipment, designed and manufactured by: INFICON Inc. Two Technology Place

Page 551 - C.2 Shipping the Canisters

3 - 6 IPN 074-471-P1B HAPSITE ER Operating Manual3.1.1 Emergency Mode (EMER MODE)In an emergency, the concentrator cleanout can be bypassed to allow

Page 552

3 - 7IPN 074-471-P1BHAPSITE ER Operating Manual3 A confirmation message will be displayed. Touch Yes or push OK SEL to continue. See Figure 3-11.Fig

Page 553 - C.3 Empty Canisters

3 - 8 IPN 074-471-P1B HAPSITE ER Operating ManualFigure 3-13 EMER Mode Inactive6 The HAPSITE ER will run a concentrator cleanout and prepare for gen

Page 554

3 - 9IPN 074-471-P1BHAPSITE ER Operating ManualFigure 3-15 Concentrator Cleanout3 The HAPSITE will run a concentrator cleanout. See Figure 3-16.Fig

Page 555 - Index - 1

3 - 10 IPN 074-471-P1B HAPSITE ER Operating Manual3.1.2.2 Skip Cleanout1 Touch CONC OPTIONS or use the arrow keys to highlight the CONC OPTIONS butt

Page 556

3 - 11IPN 074-471-P1BHAPSITE ER Operating Manual3.1.3 Concentrator Cleanout FailureIf the concentrator cleanout is successful, the screen will disp

Page 557 - Index - 3

3 - 12 IPN 074-471-P1B HAPSITE ER Operating Manual3.1.4 Quick Reference SOP - Heat-up and TuneCAUTIONDo not open the front panel in a wet or contami

Page 558

3 - 13IPN 074-471-P1BHAPSITE ER Operating Manual3.2 Selecting a Different Method Using the SELECT METHOD IconIf the default method is not the desir

Page 559 - Index - 5

3 - 14 IPN 074-471-P1B HAPSITE ER Operating Manual3 The SYSTEM IS NOT READY screen will appear. To select a new method, touch SELECT METHOD or using

Page 560

3 - 15IPN 074-471-P1BHAPSITE ER Operating Manual5 The PREPARING message will again be displayed. See Figure 3-25. Refer to steps 4-9 of Section 3.2,